KBB1A12 - Lovato - EN50047/EN50041 limit switch
Lovato
K series limit switch with top roller plunger actuator, plastic housing in EN 50047 form factor, 1 NO + 2 NC slow-action contacts, plastic roller and bottom cable entry. K series limit switch with top roller plunger actuator, plastic housing in EN 50047 form factor, 1 NO + 2 NC slow-action contacts, plastic roller and bottom cable entry.
MPNs KBB1A12, LOVKBB1A12
EAN 8013975150696
HS Code 85365080
Country of origin Italy
Weight
0.08 kg
The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy
Secure payments
& many more
We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods
12 Months warranty
This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty
Commercial Return Not Available
This product can only be returned in case of defects covered by the warranty.
Product information
Description
<h3>Limit switch for machine position control</h3><p>This device is used to detect machine position, travel end or mechanical presence in automation systems. The electromechanical actuation makes it suitable for guarded movements, handling equipment, conveyors and machine sequences where a physical position signal must be returned to the control circuit.</p><h4>Actuation, contacts and wiring</h4><p>actuator top roller plunger; housing plastic; form factor EN 50047; contacts 1 NO + 2 NC; contact action slow-action; operating element plastic roller; cable entry bottom cable entry. Actuator style defines the mechanical approach of the moving part, while contact configuration and contact action define the signal delivered to the control circuit. The cable entry and housing information help place the switch correctly on the machine frame and keep wiring serviceable.</p><h4>Commissioning and service checks</h4><p>During commissioning, check the mechanical travel before energizing the circuit, then verify the signal change at the terminal level and in the machine logic. The actuator must return freely and the wiring route must not interfere with the moving part, guard or cam.</p><p>For maintenance, compare actuator type, contact layout, cable entry and operating direction before replacement. A documented position test after installation keeps the relationship between mechanical movement and electrical signal clear for future diagnostics.</p><p>In machine documentation, associate the switch signal with the exact motion step or guard state it supervises. This makes troubleshooting more direct, especially when several similar position devices are wired to the same control panel or safety-related sequence.</p>
<h3>Limit switch for machine position control</h3><p>This device is used to detect machine position, travel end or mechanical presence in automation systems. The electromechanical actuation makes it suitable for guarded movements, handling equipment, conveyors and machine sequences where a physical position signal must be returned to the control circuit.</p><h4>Actuation, contacts and wiring</h4><p>actuator top roller plunger; housing plastic; form factor EN 50047; contacts 1 NO + 2 NC; contact action slow-action; operating element plastic roller; cable entry bottom cable entry. Actuator style defines the mechanical approach of the moving part, while contact configuration and contact action define the signal delivered to the control circuit. The cable entry and housing information help place the switch correctly on the machine frame and keep wiring serviceable.</p><h4>Commissioning and service checks</h4><p>During commissioning, check the mechanical travel before energizing the circuit, then verify the signal change at the terminal level and in the machine logic. The actuator must return freely and the wiring route must not interfere with the moving part, guard or cam.</p><p>For maintenance, compare actuator type, contact layout, cable entry and operating direction before replacement. A documented position test after installation keeps the relationship between mechanical movement and electrical signal clear for future diagnostics.</p><p>In machine documentation, associate the switch signal with the exact motion step or guard state it supervises. This makes troubleshooting more direct, especially when several similar position devices are wired to the same control panel or safety-related sequence.</p>
Technical specifications
- Degree of protection (IP)
- IP65
- Ambient temperature during operating
- -25;70 °C
- Housing material
- Plastic
- Number of contacts as normally closed contact
- 1
- Number of contacts as normally open contact
- 1
- Type of electric connection
- Cable entry metrical
- Explosion safety category for gas
- None
- Explosion safety category for dust
- None
- Type of interface
- None
- Forced opening
- TRUE
- Coating housing
- Other
- Type of interface for safety communication
- None
- Construction type housing
- Cuboid
- Width sensor
- 30 mm
- Height of sensor
- 85 mm
- Length of sensor
- 30 mm
- Switching function
- Slow-action switch with overlapping
- Type of control element
- Roller cam
- Diameter sensor
- 11 mm
- Alignment of the control element
- Roller cam straight