MCA201 HAGER MCB 6000A 10kA 2P curve C 1A 2 modules

The miniature circuit breaker ensures reliable protection with a breaking capacity (Icn) of 6000 A according to CEI EN 60898-1 and (Icu) 10 kA according to CEI EN 60947-2. It operates at 230 V (Un) at 50-60 Hz and is ideal for residential and tertiary installations, protecting against overloads and short circuits. Equipped with 2 protected poles, C curve and rated current (In) of 1 A, it occupies 2 DIN modules. The miniature circuit breaker ensures reliable protection with a breaking capacity (Icn) of 6000 A according to CEI EN 60898-1 and (Icu) 10 kA according to CEI EN 60947-2. It operates at 230 V (Un) at 50-60 Hz and is ideal for residential and tertiary installations, protecting against overloads and short circuits. Equipped with 2 protected poles, C curve and rated current (In) of 1 A, it occupies 2 DIN modules.

MPNs MCA201, HAGMCA201
EAN 3250614346576
Código HS 85362010
País de origen Polonia
Weight 0.23 kg
Peso volumétrico 61.33 kg

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

4 Disponible en los socios Precio y entrega a solicitud de presupuesto
Debes estar registrado

Información del producto

Especificaciones técnicas

Degree of protection (IP)
IP20
Ambient temperature during operating
-25;70 °C
Voltage type
AC
Rated voltage
400 V
Connectable conductor cross section solid-core
1;35 mm²
Connectable conductor cross section multi-wired
1;25 mm²
Rated current
1 A
Width in number of modular spacings
2
Power loss
2.11 W
Built-in depth
70 mm
Frequency
50;60 Hz
Flush-mounted installation
TRUE
Rated insulation voltage Ui
500 V
Pollution degree
2
Additional equipment possible
TRUE
Rated impulse withstand voltage Uimp
6 kV
Release characteristic
C
Over voltage category
3
Number of protected poles
2
Number of poles (total)
2
Current limiting class
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
20 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
10 kA