VBA-2E-G11-I/U/PT100-F PEPPERL+FUCHS - Part number: 222331
Agotado - Backorder
A pedido del fabricante
410,69 USD

Impuestos de importación excluidos

Debes estar registrado

VBA-2E-G11-I/U/PT100-F PEPPERL+FUCHS - Part number: 222331

PEPPERL+FUCHS

AS-Interface analog module VBA-2E-G11-I/U/PT100-F VBA-2E-G11-I/U/PT100-F Addressing jack Function display for bus, internal and external sensor power supply, inputs Supply for inputs from AS-Interface or auxiliary voltage Degree of protection IP68 / IP69K Accuracy ± 0.1 % Integrated shielding Channel-specific input monitoring Inputs for current, voltage or Pt100 temperature sensor AS-Interface analog module VBA-2E-G11-I/U/PT100-F VBA-2E-G11-I/U/PT100-F Addressing jack Function display for bus, internal and external sensor power supply, inputs Supply for inputs from AS-Interface or auxiliary voltage Degree of protection IP68 / IP69K Accuracy ± 0.1 % Integrated shielding Channel-specific input monitoring Inputs for current, voltage or Pt100 temperature sensor

MPNs 222331, PEP222331, VBA-2E-G11-I/U/PT100-F
Código HS 85371091
Weight 0.2 kg

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.
Vendido por PLC-CITY® y enviado desde Italia

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

410,69 USD

Impuestos de importación excluidos

Debes estar registrado
Vendido por PLC-CITY® y enviado desde Italia
Somos Socio Especialista de PEPPERL+FUCHS
Envío exprés gratuito a Estados Unidos
Loader...
Ver todos los servicios de envío
Solicite un presupuesto para conocer la fecha de entrega

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

Debes estar registrado

Solicite su servicio técnico personalizado

Confíe en nuestro equipo técnico experto para una gama de servicios personalizados: reparación, programación, mantenimiento y mucho más.

Información del producto

Descripción

Extracto de la hoja de datos: Información técnica del  VBA-2E-G11-I/U/PT100-F Descripción del producto G11 analog module2 analog inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 60 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V Pt100: -200 ... 850 °C Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Current loading capacity≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Measuring currentfor Pt100: approx. 1 mA AccuracyVoltage/current: 0.1% of accumulated value Pt100: 0.1% of indicated temperature [°C] + 0.3 °C Resolution16 Bit / 1 µA (current input) or16 bit / 1 mV (voltage input) or16 Bit / 0.1°C (temperature input) Temperature influenceVoltage/current: 20 ppm/KPt100: (10 ppm of indicated temperature [°C] + 0.003 °C)/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Extracto de la hoja de datos: Información técnica del  VBA-2E-G11-I/U/PT100-F Descripción del producto G11 analog module2 analog inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 60 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V Pt100: -200 ... 850 °C Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Current loading capacity≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Measuring currentfor Pt100: approx. 1 mA AccuracyVoltage/current: 0.1% of accumulated value Pt100: 0.1% of indicated temperature [°C] + 0.3 °C Resolution16 Bit / 1 µA (current input) or16 bit / 1 mV (voltage input) or16 Bit / 0.1°C (temperature input) Temperature influenceVoltage/current: 20 ppm/KPt100: (10 ppm of indicated temperature [°C] + 0.003 °C)/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

Las opiniones de nuestros clientes