VAA-4A-G12-EA2L PEPPERL+FUCHS - Part number: 194614
Agotado - Backorder
A pedido del fabricante
268,33 USD

Impuestos de importación excluidos

Debes estar registrado

VAA-4A-G12-EA2L PEPPERL+FUCHS - Part number: 194614

PEPPERL+FUCHS

AS-Interface actuator module VAA-4A-G12-EA2L VAA-4A-G12-EA2L One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable DIN rail mounting AS-Interface certificate AS-Interface actuator module VAA-4A-G12-EA2L VAA-4A-G12-EA2L One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable DIN rail mounting AS-Interface certificate

MPNs 194614, PEP194614, VAA-4A-G12-EA2L
Código HS 85371091
Weight 0.2 kg

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.
Vendido por PLC-CITY® y enviado desde Italia

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

268,33 USD

Impuestos de importación excluidos

Debes estar registrado
Vendido por PLC-CITY® y enviado desde Italia
Somos Socio Especialista de PEPPERL+FUCHS
Envío exprés gratuito a Estados Unidos
Loader...
Ver todos los servicios de envío
Solicite un presupuesto para conocer la fecha de entrega

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

Debes estar registrado

Información del producto

Descripción

Extracto de la hoja de datos: Información técnica del  VAA-4A-G12-EA2L Descripción del producto G12 flat module4 electronic outputs (PNP) General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd230 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED OUTSwitching status (output); 4 yellow/red LEDs Yellow: output activeRed: output overload Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Output Number/Type4 electronic outputs, PNP Supplyfrom external auxiliary voltage UAUX Current2 A per output6 A total (TB ≤ 40 °C)4 A total (TB ≤ 70 °C) Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 Programming instructions ProfileS-8.1 IO code8 ID code1 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 - OUT1 D1 - OUT2 D2 - OUT3 D3 - OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass200 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Extracto de la hoja de datos: Información técnica del  VAA-4A-G12-EA2L Descripción del producto G12 flat module4 electronic outputs (PNP) General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd230 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED OUTSwitching status (output); 4 yellow/red LEDs Yellow: output activeRed: output overload Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Output Number/Type4 electronic outputs, PNP Supplyfrom external auxiliary voltage UAUX Current2 A per output6 A total (TB ≤ 40 °C)4 A total (TB ≤ 70 °C) Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 Programming instructions ProfileS-8.1 IO code8 ID code1 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 - OUT1 D1 - OUT2 D2 - OUT3 D3 - OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass200 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Las opiniones de nuestros clientes