VAA-4E4A-G4-ZE/E2 PEPPERL+FUCHS - Part number: 188589
Agotado - Backorder
A pedido del fabricante
380,89 USD

Impuestos de importación excluidos

Debes estar registrado

VAA-4E4A-G4-ZE/E2 PEPPERL+FUCHS - Part number: 188589

PEPPERL+FUCHS

AS-Interface sensor/actuator module VAA-4E4A-G4-ZE/E2 VAA-4E4A-G4-ZE/E2 Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Communication monitoring, turn-off Inputs for 2- and 3-wire sensors Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs Monitoring of sensor overloads AS-Interface sensor/actuator module VAA-4E4A-G4-ZE/E2 VAA-4E4A-G4-ZE/E2 Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Communication monitoring, turn-off Inputs for 2- and 3-wire sensors Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs Monitoring of sensor overloads

MPNs 188589, PEP188589, VAA-4E4A-G4-ZE/E2
Código HS 85371091
Weight 0.35 kg

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.
Vendido por PLC-CITY® y enviado desde Italia

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

380,89 USD

Impuestos de importación excluidos

Debes estar registrado
Vendido por PLC-CITY® y enviado desde Italia
Somos Socio Especialista de PEPPERL+FUCHS
Envío exprés gratuito a Estados Unidos
Loader...
Ver todos los servicios de envío
Solicite un presupuesto para conocer la fecha de entrega

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

Debes estar registrado

Solicite su servicio técnico personalizado

Confíe en nuestro equipo técnico experto para una gama de servicios personalizados: reparación, programación, mantenimiento y mucho más.

Información del producto

Descripción

Extracto de la hoja de datos: Información técnica del  VAA-4E4A-G4-ZE/E2 Descripción del producto G4 module IP654 inputs (PNP) and 4 electronic outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd150 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULTdual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply or outputs LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 230 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 160 mA (TB ≤ 60 °C), short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current1 A per output, 4 A total Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals Material HousingPA 6 GF30 Mass350 g Tightening torque, housing screws0.8 Nm MountingDIN rail or screw mounting Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Extracto de la hoja de datos: Información técnica del  VAA-4E4A-G4-ZE/E2 Descripción del producto G4 module IP654 inputs (PNP) and 4 electronic outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd150 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULTdual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply or outputs LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 230 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 160 mA (TB ≤ 60 °C), short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current1 A per output, 4 A total Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals Material HousingPA 6 GF30 Mass350 g Tightening torque, housing screws0.8 Nm MountingDIN rail or screw mounting Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Las opiniones de nuestros clientes