VAA-4E4A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 186880
Agotado - Backorder
A pedido del fabricante
275,68 USD

Impuestos de importación excluidos

Debes estar registrado

VAA-4E4A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 186880

PEPPERL+FUCHS

AS-Interface sensor/actuator module VAA-4E4A-KE1-Z/E2 VAA-4E4A-KE1-Z/E2 Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of the inputs and outputs from the external auxiliary voltage Function display for bus, ext. auxiliary voltage, inputs and outputs AS-Interface sensor/actuator module VAA-4E4A-KE1-Z/E2 VAA-4E4A-KE1-Z/E2 Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of the inputs and outputs from the external auxiliary voltage Function display for bus, ext. auxiliary voltage, inputs and outputs

MPNs 186880, PEP186880, VAA-4E4A-KE1-Z/E2
Código HS 85371091
Weight N/A

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.
Vendido por PLC-CITY® y enviado desde Italia

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

275,68 USD

Impuestos de importación excluidos

Debes estar registrado
Vendido por PLC-CITY® y enviado desde Italia
Somos Socio Especialista de PEPPERL+FUCHS
Envío exprés gratuito a Estados Unidos
Loader...
Ver todos los servicios de envío
Solicite un presupuesto para conocer la fecha de entrega

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

Debes estar registrado

Información del producto

Descripción

Extracto de la hoja de datos: Información técnica del  VAA-4E4A-KE1-Z/E2 Descripción del producto KE1 switch cabinet module4 inputs and 4 outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE87056 Functional safety related parameters MTTFd90 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom external auxiliary voltage UAUX Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current0.5 A per output , 2 A per module Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2015 Emitted interferenceEN 55011:2009 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61326-1:2006 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable spring double terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Extracto de la hoja de datos: Información técnica del  VAA-4E4A-KE1-Z/E2 Descripción del producto KE1 switch cabinet module4 inputs and 4 outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE87056 Functional safety related parameters MTTFd90 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom external auxiliary voltage UAUX Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current0.5 A per output , 2 A per module Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2015 Emitted interferenceEN 55011:2009 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61326-1:2006 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable spring double terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Las opiniones de nuestros clientes