VBA-4E4A-KE5-ZEJQ/E2L PEPPERL+FUCHS - Part number: 263813
Agotado - Backorder
A pedido del fabricante
263,76 USD

Impuestos de importación excluidos

Debes estar registrado

VBA-4E4A-KE5-ZEJQ/E2L PEPPERL+FUCHS - Part number: 263813

PEPPERL+FUCHS

AS-Interface sensor/actuator module VBA-4E4A-KE5-ZEJQ/E2L VBA-4E4A-KE5-ZEJQ/E2L Housing with push-in connection technology and mechanically coded terminal blocks Housing width 19 mm, installation in the switch cabinet on DIN mounting rail Selectable supply to the sensors: External or from the module Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs Red LED per channel, lights up in the event of output overload AS-Interface sensor/actuator module VBA-4E4A-KE5-ZEJQ/E2L VBA-4E4A-KE5-ZEJQ/E2L Housing with push-in connection technology and mechanically coded terminal blocks Housing width 19 mm, installation in the switch cabinet on DIN mounting rail Selectable supply to the sensors: External or from the module Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs Red LED per channel, lights up in the event of output overload

MPNs 263813, PEP263813, VBA-4E4A-KE5-ZEJQ/E2L
Código HS 85371091
Weight 0.11 kg

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.
Vendido por PLC-CITY® y enviado desde Italia

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

263,76 USD

Impuestos de importación excluidos

Debes estar registrado
Vendido por PLC-CITY® y enviado desde Italia
Somos Socio Especialista de PEPPERL+FUCHS
Envío exprés gratuito a Estados Unidos
Loader...
Ver todos los servicios de envío
Solicite un presupuesto para conocer la fecha de entrega

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

Debes estar registrado

Información del producto

Descripción

Extracto de la hoja de datos: Información técnica del  VBA-4E4A-KE5-ZEJQ/E2L Descripción del producto Cabinet module4 inputs and 4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specification≥ V3.0 UL File NumberE223772 MTBF141 a Indicators/operating means LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA (without sensors) / max. 190 mA Protection classIII Surge protectionUEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Overvoltage category of the power supplies (primary): III Rated insulation voltage92 V Pulse withstand voltage0.8 kV Input Number/Type4 inputs for 3-wire sensors (PNP), DC Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) Voltage21 ... 31 V DC (INT) Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT) Input current≤ 5.6 mA (max.) Switching pointaccording to DIN EN 61131-2 (type 1) 0 (unattenuated)≤ 0.5 mA 1 (attenuated)≥ 2 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A Per output, total 4 A (TB ≤ 60 °C) 1 A Per output, total 4 A (TB ≤ 70 °C) Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Machinery Directive Directive 2006/42/ECEN ISO 13849-1:2008 EN ISO 13849-2:2012 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 61140:2009 InputEN 61131-2:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Functional safetyEN ISO 13849-1:2008 EN ISO 13849-2:2012 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 For safety applications: Installation in an enclosure with a minimum protection class of IP54 required ConnectionRemovable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass110 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Extracto de la hoja de datos: Información técnica del  VBA-4E4A-KE5-ZEJQ/E2L Descripción del producto Cabinet module4 inputs and 4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specification≥ V3.0 UL File NumberE223772 MTBF141 a Indicators/operating means LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA (without sensors) / max. 190 mA Protection classIII Surge protectionUEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Overvoltage category of the power supplies (primary): III Rated insulation voltage92 V Pulse withstand voltage0.8 kV Input Number/Type4 inputs for 3-wire sensors (PNP), DC Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) Voltage21 ... 31 V DC (INT) Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT) Input current≤ 5.6 mA (max.) Switching pointaccording to DIN EN 61131-2 (type 1) 0 (unattenuated)≤ 0.5 mA 1 (attenuated)≥ 2 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A Per output, total 4 A (TB ≤ 60 °C) 1 A Per output, total 4 A (TB ≤ 70 °C) Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Machinery Directive Directive 2006/42/ECEN ISO 13849-1:2008 EN ISO 13849-2:2012 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 61140:2009 InputEN 61131-2:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Functional safetyEN ISO 13849-1:2008 EN ISO 13849-2:2012 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 For safety applications: Installation in an enclosure with a minimum protection class of IP54 required ConnectionRemovable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass110 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Las opiniones de nuestros clientes