IQT1-FP-IO-V1 PEPPERL+FUCHS - Part number: 299929
Agotado - Backorder
A pedido del fabricante
640,16 USD

Impuestos de importación excluidos

Debes estar registrado

IQT1-FP-IO-V1 PEPPERL+FUCHS - Part number: 299929

PEPPERL+FUCHS

Thru-beam sensor OBE12M-R101-SEP-IO-V3 OBE12M-R101-SEP-IO-V3 Miniature design with versatile mounting options IO-link interface for service and process data Various frequencies for avoiding mutual interference (cross-talk immunity) Extended temperature range-40°C ... 60°C High degree of protection IP69K Thru-beam sensor OBE12M-R101-SEP-IO-V3 OBE12M-R101-SEP-IO-V3 Miniature design with versatile mounting options IO-link interface for service and process data Various frequencies for avoiding mutual interference (cross-talk immunity) Extended temperature range-40°C ... 60°C High degree of protection IP69K

MPNs 299929, PEP299929, IQT1-FP-IO-V1
Código HS 85176200
Weight 0.38 kg

La imagen del producto es solo para fines ilustrativos.
El país de origen, el código del HS y la descripción son proporcionados por el fabricante y pueden estar sujetos a cambios sin previo aviso. Por esta razón, PLC-City no puede ser responsable de las discrepancias.
Vendido por PLC-CITY® y enviado desde Italia

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

640,16 USD

Impuestos de importación excluidos

Debes estar registrado
Vendido por PLC-CITY® y enviado desde Italia
Somos Socio Especialista de PEPPERL+FUCHS
Envío exprés gratuito a Estados Unidos
Loader...
Ver todos los servicios de envío
Solicite un presupuesto para conocer la fecha de entrega

Aceptamos muchos métodos de pago: Transferencia bancaria (SEPA, ACH), Tarjetas de débito/ crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, enlace por Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCPay.
Más información sobre nuestros métodos de pago

Este producto está cubierto por una garantía 12 Meses válida para defectos de fabricación o mal funcionamiento. La garantía no cubre los daños causados por un uso inadecuado o daños accidentales.
Más información sobre nuestra garantía

Las devoluciones están sujetas a autorización previa y se reembolsarán con un crédito en tienda. Se excluyen los artículos en backorder.

Ver nuestra política de devoluciones

Obtenga su presupuesto personalizado ahora

Un representante de ventas dedicado le ayudará a ofrecer el mejor precio y plazos de entrega.

Debes estar registrado

Solicite su servicio técnico personalizado

Confíe en nuestro equipo técnico experto para una gama de servicios personalizados: reparación, programación, mantenimiento y mucho más.

Información del producto

Descripción

Extracto de la hoja de datos: Información técnica del  IQT1-FP-IO-V1 Descripción del producto HF read/write station with IO-Link in accordance with ISO 15693 General specifications Operating frequency13.56 MHz Transfer rate26 kBit/s Sensing range Read distance0 ... 130 mm Write distance0 ... 130 mm Widthmax. 100 mm UL File NumberE87056 Functional safety related parameters MTTFd280 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means LED red/greenGreen: power onFlashing green: IO-Link communicationFlashing red/green: IO-Link communication interrupted LED blue/yellowBlue: Write/read attempt performedYellow: Read/write tag detected Electrical specifications Rated operating voltage20 ... 30 V DC , ripple 10 %SS No-load supply current≤ 70 mA (at 24 V DC) Power consumption≤ 2 W Interface Interface typeIO-Link IO-Link revision1.1 Vendor ID1 (0x0001) Device ID4194561 (0x400101) Data transfer rateCOM3 (230.4 kbits/s) Min. cycle time4 ms SIO mode supportno Compatible master port typeClass A Class B Directive conformity Radio equipment Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 RoHS Directive 2011/65/EU (RoHS)IEC/EN 63000 Standard conformity Degree of protectionEN 60529 Communication interfaceIEC 61131-9 / IO-Link V1.1.2 RFIDISO/IEC 15693-2 ISO/IEC 15693-3 ISO/IEC 18000-3 Approvals and certificates UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. MIC approvalAC-21098 Radio approvalUSA: FCC IREIQT1FPIOCanada: 7037A-IQT1FPIO Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Housing length108.5 mm Housing width80 mm Housing height40 mm Degree of protectionIP67 Connectionconnector M12 x 1 Material HousingPBT Basediecast aluminum Encapsulation compoundCY 221/HY 2966 Installation Distance between two heads≥ 150 mm Massapprox. 380 g Classifications SystemClasscode ECLASS 11.027280401 ECLASS 10.0.127280401 ECLASS 9.027280401 ECLASS 8.027280401 ECLASS 5.127280401 ETIM 8.0EC002998 ETIM 7.0EC002998 ETIM 6.0EC002998 ETIM 5.0EC002998 UNSPSC 12.143211710 Extracto de la hoja de datos: Información técnica del  IQT1-FP-IO-V1 Descripción del producto HF read/write station with IO-Link in accordance with ISO 15693 General specifications Operating frequency13.56 MHz Transfer rate26 kBit/s Sensing range Read distance0 ... 130 mm Write distance0 ... 130 mm Widthmax. 100 mm UL File NumberE87056 Functional safety related parameters MTTFd280 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means LED red/greenGreen: power onFlashing green: IO-Link communicationFlashing red/green: IO-Link communication interrupted LED blue/yellowBlue: Write/read attempt performedYellow: Read/write tag detected Electrical specifications Rated operating voltage20 ... 30 V DC , ripple 10 %SS No-load supply current≤ 70 mA (at 24 V DC) Power consumption≤ 2 W Interface Interface typeIO-Link IO-Link revision1.1 Vendor ID1 (0x0001) Device ID4194561 (0x400101) Data transfer rateCOM3 (230.4 kbits/s) Min. cycle time4 ms SIO mode supportno Compatible master port typeClass A Class B Directive conformity Radio equipment Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 RoHS Directive 2011/65/EU (RoHS)IEC/EN 63000 Standard conformity Degree of protectionEN 60529 Communication interfaceIEC 61131-9 / IO-Link V1.1.2 RFIDISO/IEC 15693-2 ISO/IEC 15693-3 ISO/IEC 18000-3 Approvals and certificates UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. MIC approvalAC-21098 Radio approvalUSA: FCC IREIQT1FPIOCanada: 7037A-IQT1FPIO Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Housing length108.5 mm Housing width80 mm Housing height40 mm Degree of protectionIP67 Connectionconnector M12 x 1 Material HousingPBT Basediecast aluminum Encapsulation compoundCY 221/HY 2966 Installation Distance between two heads≥ 150 mm Massapprox. 380 g Classifications SystemClasscode ECLASS 11.027280401 ECLASS 10.0.127280401 ECLASS 9.027280401 ECLASS 8.027280401 ECLASS 5.127280401 ETIM 8.0EC002998 ETIM 7.0EC002998 ETIM 6.0EC002998 ETIM 5.0EC002998 UNSPSC 12.143211710

Las opiniones de nuestros clientes