Din multi / o bar Mitsubischi Electric - Code de commande: YSKCIO2B
Rupture de stock - Backorder
A commander auprès du fabricant
262,63 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

Din multi / o bar Mitsubischi Electric - Code de commande: YSKCIO2B

Riello UPS

Multi I/O interface in DIN rail version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces. Multi I/O interface in DIN rail version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces.

MPNs YSKCIO2B, RIEYSKCIO2B
EAN 8023251009778
Code SH 85072000
Weight 1.5 kg
Poids volumétrique 2.68 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

262,63 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un revendeur agréé de Riello UPS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

<div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface DIN rail version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: DIN rail version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div> <div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface DIN rail version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: DIN rail version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div>

Spécifications Techniques

Type d'accessoire
Autre

Avis sur notre entreprise