Netman 204 4 Go ru Mitsubischi Electric - Code de commande: YSKCSA4BRU

Riello UPS

Network card for UPS management via LAN, with support for environmental sensors and integration with supervision software. It enables remote monitoring, events, measurements and alarms; sensor capacity up to 6 independent units according to NetMan 204 documentation. Riello compatibility: Riello UPS systems prepared for NetMan cards. Network card for UPS management via LAN, with support for environmental sensors and integration with supervision software. It enables remote monitoring, events, measurements and alarms; sensor capacity up to 6 independent units according to NetMan 204 documentation. Riello compatibility: Riello UPS systems prepared for NetMan cards.

MPNs YSKCSA4BRU, RIEYSKCSA4BRU
EAN 8023251007644
Code SH 85072000
Pays d'origine Italie
Weight 0.21 kg
Poids volumétrique 0.42 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

2 Disponible auprès des partenaires Prix ​​et livraison sur demande de devis
Vous devez être connecté à votre compte client

Informations sur les produits

La description

<div class="row"> <div class="col-xs-12"> <h3>Network card for UPS monitoring</h3> <p>Network card for UPS systems designed to integrate the protected power system into LAN infrastructures and supervision software. It enables remote monitoring of UPS statuses, events, parameters and alarms, improving management of data centers, server rooms and technical installations. NetMan 204 documentation indicates the possibility of managing up to 6 independent sensors, useful for controlling environmental conditions and signals in the protected area. Integration with shutdown and supervision software allows notifications and shutdown procedures to be automated when operating conditions require it.</p> <h4>Technical features</h4> <ul> <li>UPS management via LAN network.</li> <li>Monitoring of statuses, measurements, events and alarms.</li> <li>Support for up to 6 independent sensors according to documentation.</li> <li>Integration with environmental sensors for temperature, humidity or I/O control.</li> </ul> <h4>Integration process</h4> <p>Installation includes card insertion, IP configuration, access definition, possible sensor connection and notification testing. For critical environments it is recommended to document shutdown and alarm policies.</p> <h4>Configuration software</h4> <p>It can work with supervision and shutdown software such as PowerShield3 and PowerNetGuard according to the installation configuration. Programming concerns network parameters, notifications, users, sensors and thresholds. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Riello UPS systems prepared for NetMan cards.</p> </div> </div> <div class="row"> <div class="col-xs-12"> <h3>Network card for UPS monitoring</h3> <p>Network card for UPS systems designed to integrate the protected power system into LAN infrastructures and supervision software. It enables remote monitoring of UPS statuses, events, parameters and alarms, improving management of data centers, server rooms and technical installations. NetMan 204 documentation indicates the possibility of managing up to 6 independent sensors, useful for controlling environmental conditions and signals in the protected area. Integration with shutdown and supervision software allows notifications and shutdown procedures to be automated when operating conditions require it.</p> <h4>Technical features</h4> <ul> <li>UPS management via LAN network.</li> <li>Monitoring of statuses, measurements, events and alarms.</li> <li>Support for up to 6 independent sensors according to documentation.</li> <li>Integration with environmental sensors for temperature, humidity or I/O control.</li> </ul> <h4>Integration process</h4> <p>Installation includes card insertion, IP configuration, access definition, possible sensor connection and notification testing. For critical environments it is recommended to document shutdown and alarm policies.</p> <h4>Configuration software</h4> <p>It can work with supervision and shutdown software such as PowerShield3 and PowerNetGuard according to the installation configuration. Programming concerns network parameters, notifications, users, sensors and thresholds. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Riello UPS systems prepared for NetMan cards.</p> </div> </div>

Spécifications Techniques

Type d'accessoire
Adaptateur SNMP/Web

Avis sur notre entreprise