KFU8-UFC-1.D.FA PEPPERL+FUCHS - Part number: 282274
Rupture de stock - Backorder
A commander auprès du fabricant
731,49 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

KFU8-UFC-1.D.FA PEPPERL+FUCHS - Part number: 282274

PEPPERL+FUCHS

Thru-beam sensor (pair) OBE25M-R201-SEP-IO-V3 OBE25M-R201-SEP-IO-V3 Medium design with versatile mounting options IO-link interface for service and process data Various frequencies for avoiding mutual interference (cross-talk immunity) Extended temperature range-40°C ... 60°C High degree of protection IP69K Thru-beam sensor (pair) OBE25M-R201-SEP-IO-V3 OBE25M-R201-SEP-IO-V3 Medium design with versatile mounting options IO-link interface for service and process data Various frequencies for avoiding mutual interference (cross-talk immunity) Extended temperature range-40°C ... 60°C High degree of protection IP69K

MPNs 282274, PEP282274, KFU8-UFC-1.D.FA
Code SH 90318000
Weight 0.3 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

731,49 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  KFU8-UFC-1.D.FA General specifications Signal typeDigital Input Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Power dissipation/power consumption≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA Interface Programming interfaceprogramming socket Input Connection sidefield side ConnectionInput I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3 input II: terminals 13+, 14- start-up override; Input I2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current22 V / 40 mA Input resistance4.7 kΩ Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse duration> 50 µs Input frequency0.001 ... 10000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12output II: terminals 16, 17, 18outout III: terminasl 19+, 20-output IV: terminals 8+, 7- Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output IIIelectronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output IVanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43) Transfer characteristics Input I Measurement range0.001 ... 10000 Hz Resolution0.1 % of the measurement value , ≥ 0.001 Hz Accuracy0.1 % of the measurement value , > 0.001 Hz Measuring time< 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output IV Resolution< 10 µA Accuracy< 20 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Start-up override/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output IIIbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-UFC-1.D.FA General specifications Signal typeDigital Input Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 23, 24 Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Power dissipation/power consumption≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA Interface Programming interfaceprogramming socket Input Connection sidefield side ConnectionInput I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3 input II: terminals 13+, 14- start-up override; Input I2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact Open circuit voltage/short-circuit current22 V / 40 mA Input resistance4.7 kΩ Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA Pulse duration> 50 µs Input frequency0.001 ... 10000 Hz Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA Open circuit voltage/short-circuit current18 V / 5 mA Output Connection sidecontrol side Connectionoutput I: terminals 10, 11, 12output II: terminals 16, 17, 18outout III: terminasl 19+, 20-output IV: terminals 8+, 7- Output I, IIsignal, relay Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A Mechanical life5 x 107 switching cycles Energized/De-energized delay20 ms / 20 ms Output IIIelectronic output, passive Contact loading40 V DC Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA) Output IVanalog Current range0 ... 20 mA or 4 ... 20 mA Open loop voltagemax. 24 V DC Loadmax. 650 Ω Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43) Transfer characteristics Input I Measurement range0.001 ... 10000 Hz Resolution0.1 % of the measurement value , ≥ 0.001 Hz Accuracy0.1 % of the measurement value , > 0.001 Hz Measuring time< 100 ms Influence of ambient temperature0.003 %/K (30 ppm) Output I, II Response delay≤ 200 ms Output IV Resolution< 10 µA Accuracy< 20 µA Influence of ambient temperature0.005 %/K (50 ppm) Galvanic isolation Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output III/IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Output IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Start-up override/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Interface/output IIIbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff Indicators/settings Display elementsLEDs , display Control elementsControl panel Configurationvia operating buttons via PACTware Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2006 Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass300 g Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007

Avis sur notre entreprise