VBA-2E-G4-I PEPPERL+FUCHS - Part number: 112311
Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

VBA-2E-G4-I PEPPERL+FUCHS - Part number: 112311

PEPPERL+FUCHS

AS-Interface analog module VBA-2E-G4-I VBA-2E-G4-I Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Function display for bus, external auxiliary voltage and inputs Supply of inputs external or from the module, as required AS-Interface analog module VBA-2E-G4-I VBA-2E-G4-I Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Function display for bus, external auxiliary voltage and inputs Supply of inputs external or from the module, as required

MPNs 112311, PEP112311, VBA-2E-G4-I
Code SH 85371091
Weight 0.35 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VBA-2E-G4-I Product Description G4 module IP652 analog inputs (current) General specifications Node typeStandard node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd160 a at 30 °C Indicators/operating means LED FAULTerror display; LED redred: communication errorred flashing: peripheral error LED PWRAS-Interface voltage; LED green LED ANALOGstatus input signal; LED greenoff: 1 < 1 mA (peripheral error)green: 1 mA ≤ I ≤ 1 23 mAgreen flashing: I > 23 mA (peripheral error) LED AUXext. auxiliary voltage UAUX ; LED green Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA Protection classIII Input Number/Type2 analog inputs (currrent), 4 ... 20 mA Supplyfrom AS-Interface or from external auxiliary voltage as required UAUX Current loading capacity≤ 200 mA from AS-Interface ≤ 500 mA from external auxiliary voltage UAUX Input resistance50 Ω Resolution16 Bit / 1 µA Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0mains power frequency filterP0=1, 50 Hz filter activeP0=0, 60 Hz filter active P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Message of peripheral errorP2=1, peripheral error is reportedP2=0, peripheral error is not reported P3not used Ambient conditions Ambient temperature0 ... 70 °C (32 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs: 2 x M16 x 1.5 cable glands and cage tension spring terminals, 1 x M12 x 1.5 cable gland (not used) Material HousingPA 6 GF30 Mass350 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E-G4-I Product Description G4 module IP652 analog inputs (current) General specifications Node typeStandard node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd160 a at 30 °C Indicators/operating means LED FAULTerror display; LED redred: communication errorred flashing: peripheral error LED PWRAS-Interface voltage; LED green LED ANALOGstatus input signal; LED greenoff: 1 < 1 mA (peripheral error)green: 1 mA ≤ I ≤ 1 23 mAgreen flashing: I > 23 mA (peripheral error) LED AUXext. auxiliary voltage UAUX ; LED green Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA Protection classIII Input Number/Type2 analog inputs (currrent), 4 ... 20 mA Supplyfrom AS-Interface or from external auxiliary voltage as required UAUX Current loading capacity≤ 200 mA from AS-Interface ≤ 500 mA from external auxiliary voltage UAUX Input resistance50 Ω Resolution16 Bit / 1 µA Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0mains power frequency filterP0=1, 50 Hz filter activeP0=0, 60 Hz filter active P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Message of peripheral errorP2=1, peripheral error is reportedP2=0, peripheral error is not reported P3not used Ambient conditions Ambient temperature0 ... 70 °C (32 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs: 2 x M16 x 1.5 cable glands and cage tension spring terminals, 1 x M12 x 1.5 cable gland (not used) Material HousingPA 6 GF30 Mass350 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535