VBA-4A-G11-I/U-F PEPPERL+FUCHS - Part number: 237500
Rupture de stock - Backorder
A commander auprès du fabricant
527,73 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

VBA-4A-G11-I/U-F PEPPERL+FUCHS - Part number: 237500

PEPPERL+FUCHS

AS-Interface analog module VBA-4A-G11-I/U-F VBA-4A-G11-I/U-F Addressing jack Degree of protection IP68 / IP69K Function display for bus, external auxiliary voltage and outputs Supply for outputs from AS-Interface or from bulk power Accuracy ± 0.15 % Current or voltage output Integrated shielding Channel-specific output monitoring Communication monitoring AS-Interface analog module VBA-4A-G11-I/U-F VBA-4A-G11-I/U-F Addressing jack Degree of protection IP68 / IP69K Function display for bus, external auxiliary voltage and outputs Supply for outputs from AS-Interface or from bulk power Accuracy ± 0.15 % Current or voltage output Integrated shielding Channel-specific output monitoring Communication monitoring

MPNs 237500, PEP237500, VBA-4A-G11-I/U-F
Code SH 85371091
Weight 0.2 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

527,73 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VBA-4A-G11-I/U-F Product Description G11 analog module4 analog outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd220 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGStatus of output signal; yellow LEDYellow: Output value within rangeYellow flashing: lead breakage (on current output) or output value out of range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display output supply; LED greengreen: output supply from AS-Interfaceoff: output supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 75 mA (without outputs) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Output Number/Type4 analog outputsCurrent: 0 ... 20 mAVoltage: 0 ... 10 V Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Loadvoltage output: min. 1 kΩ current output: max. 600 Ω Current loading capacity≤ 120 mA (signal current + actuator supply) from AS-Interface; overload and short-circuit protected≤ 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected ResolutionVoltage output: 3 mVCurrent output: 6 µA Accuracy0.15 % of full-scale value Temperature influence1 µA/K or 0,3 mV/K Short-circuit currentvoltage output: max. 22 mA Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.6 IO code7 ID code3 ID1 codeF ID2 code6 Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0Watchdog:P0=1 (default), watchdog activeP0=0, watchdog inactive P1Output mode:P1=1 (default), 4x current outputP2=0, 4x voltage output P2Indication of peripheral fault:P2=1 (default), peripheral fault is reportedP2=0, peripheral fault is not reported P3Automatic mode:P3=1 (default), manual setting of output modeP3=0, automatic load detection (mixed mode possible) Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Outputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4A-G11-I/U-F Product Description G11 analog module4 analog outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd220 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULTStatus display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault LED ANALOGStatus of output signal; yellow LEDYellow: Output value within rangeYellow flashing: lead breakage (on current output) or output value out of range LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INT/EXTstatus display output supply; LED greengreen: output supply from AS-Interfaceoff: output supply from auxiliary voltage Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 75 mA (without outputs) / max. 200 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Output Number/Type4 analog outputsCurrent: 0 ... 20 mAVoltage: 0 ... 10 V Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) Loadvoltage output: min. 1 kΩ current output: max. 600 Ω Current loading capacity≤ 120 mA (signal current + actuator supply) from AS-Interface; overload and short-circuit protected≤ 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected ResolutionVoltage output: 3 mVCurrent output: 6 µA Accuracy0.15 % of full-scale value Temperature influence1 µA/K or 0,3 mV/K Short-circuit currentvoltage output: max. 22 mA Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.6 IO code7 ID code3 ID1 codeF ID2 code6 Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0Watchdog:P0=1 (default), watchdog activeP0=0, watchdog inactive P1Output mode:P1=1 (default), 4x current outputP2=0, 4x voltage output P2Indication of peripheral fault:P2=1 (default), peripheral fault is reportedP2=0, peripheral fault is not reported P3Automatic mode:P3=1 (default), manual setting of output modeP3=0, automatic load detection (mixed mode possible) Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Outputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

Avis sur notre entreprise