AS-Interface Gateway/Safety Monitor VBG-PB-K30-DMD-S16-EV VBG-PB-K30-DMD-S16-EV Gateway and safety monitor in one housing Connection to PROFIBUS DP SafeLink Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs Integrated data decoupling Diagnostics via RJ45 Ethernet port AS-Interface POWER24 AS-Interface Gateway/Safety Monitor VBG-PB-K30-DMD-S16-EV VBG-PB-K30-DMD-S16-EV Gateway and safety monitor in one housing Connection to PROFIBUS DP SafeLink Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs Integrated data decoupling Diagnostics via RJ45 Ethernet port AS-Interface POWER24

MPNs 245875, PEP245875, VBG-PB-K30-DMD-S16-EV
Code SH 85176900
Weight 0.8 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

4 914,87 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VBG-PB-K30-DMD-S16-EV Product Description Gateway with integrated Safety Monitor General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Data decouplingintegrated Switch-on delay< 10 s Response delay< 40 ms UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED PROFIBUSPROFIBUS master detected; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartExternal device monitoring circuit inputs closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Electrical specifications Insulation voltage≥ 500 V Rated operating voltage30 V DC 20 ... 31.6 V (PELV) Rated operating current300 mA (PELV) Power supplymax. 4 A per AS-Interface circuit Interface 1 Interface typeRS-485 ProtocolPROFIBUS DP V1 Transfer rate9.6 kBit/s / 12 MBit/s , Automatic baud rate detection Interface 2 Interface typeEthernet: RJ-45 Diagnostic Interface Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection PROFIBUSSub-D interface AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 Fieldbus standardPROFIBUS according to DIN 19245 Part 3 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsIEC 61508:2010 (SIL3) IEC 62061:2005 (SIL3) EN ISO 13849-1:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Material HousingStainless steel Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004 Datasheet excerpt: Technical data of  VBG-PB-K30-DMD-S16-EV Product Description Gateway with integrated Safety Monitor General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Data decouplingintegrated Switch-on delay< 10 s Response delay< 40 ms UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED PROFIBUSPROFIBUS master detected; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartExternal device monitoring circuit inputs closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Electrical specifications Insulation voltage≥ 500 V Rated operating voltage30 V DC 20 ... 31.6 V (PELV) Rated operating current300 mA (PELV) Power supplymax. 4 A per AS-Interface circuit Interface 1 Interface typeRS-485 ProtocolPROFIBUS DP V1 Transfer rate9.6 kBit/s / 12 MBit/s , Automatic baud rate detection Interface 2 Interface typeEthernet: RJ-45 Diagnostic Interface Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection PROFIBUSSub-D interface AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 Fieldbus standardPROFIBUS according to DIN 19245 Part 3 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsIEC 61508:2010 (SIL3) IEC 62061:2005 (SIL3) EN ISO 13849-1:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Material HousingStainless steel Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004

Avis sur notre entreprise