PEPPERL+FUCHS

AS-Interface gateway VBG-PN-K20-DMD VBG-PN-K20-DMD Gateway compliant with AS-Interface specification 3.0 Connection to PROFINET IO Fault diagnosis via LEDs and grafic display Easy commissioning by graphic display AS-Interface monitor or extended AS-Interface diagnostic read via display Dublicate addressing detection Earth fault detection AS-Interface noise detection All AS-Interface functions possible via Ethernet Commissioning, locally on the gateway or via AS-i Control Tools software Ethernet diagnostic interface 2 AS-Interface networks AS-Interface gateway VBG-PN-K20-DMD VBG-PN-K20-DMD Gateway compliant with AS-Interface specification 3.0 Connection to PROFINET IO Fault diagnosis via LEDs and grafic display Easy commissioning by graphic display AS-Interface monitor or extended AS-Interface diagnostic read via display Dublicate addressing detection Earth fault detection AS-Interface noise detection All AS-Interface functions possible via Ethernet Commissioning, locally on the gateway or via AS-i Control Tools software Ethernet diagnostic interface 2 AS-Interface networks

MPNs 219010, PEP219010, VBG-PN-K20-DMD
Code SH 85176900
Weight 0.5 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VBG-PN-K20-DMD Product Description PROFINET Gateway, double master for 2 AS-Interface networks with integrated switch General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters MTTFd100 a at 30 °C Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface circuit 1≤ 200 mA from AS-Interface circuit 2 ≤ 270 mA in total Interface 1 Interface typePROFINET I / O device (IRT) Physical 2 x RJ-45 ProtocolMedia Redundancy Protocol (MRP) Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Interface 3 Interface typeChip card slot Connection PROFINETRJ-45 AS-Interfaceremovable spring clamp terminals Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass500 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBG-PN-K20-DMD Product Description PROFINET Gateway, double master for 2 AS-Interface networks with integrated switch General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters MTTFd100 a at 30 °C Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface circuit 1≤ 200 mA from AS-Interface circuit 2 ≤ 270 mA in total Interface 1 Interface typePROFINET I / O device (IRT) Physical 2 x RJ-45 ProtocolMedia Redundancy Protocol (MRP) Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Interface 3 Interface typeChip card slot Connection PROFINETRJ-45 AS-Interfaceremovable spring clamp terminals Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass500 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535