VAA-4A-G12-EA2L PEPPERL+FUCHS - Part number: 194614
Rupture de stock - Backorder
A commander auprès du fabricant
268,33 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

VAA-4A-G12-EA2L PEPPERL+FUCHS - Part number: 194614

PEPPERL+FUCHS

AS-Interface actuator module VAA-4A-G12-EA2L VAA-4A-G12-EA2L One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable DIN rail mounting AS-Interface certificate AS-Interface actuator module VAA-4A-G12-EA2L VAA-4A-G12-EA2L One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable DIN rail mounting AS-Interface certificate

MPNs 194614, PEP194614, VAA-4A-G12-EA2L
Code SH 85371091
Weight 0.2 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

268,33 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VAA-4A-G12-EA2L Product Description G12 flat module4 electronic outputs (PNP) General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd230 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED OUTSwitching status (output); 4 yellow/red LEDs Yellow: output activeRed: output overload Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Output Number/Type4 electronic outputs, PNP Supplyfrom external auxiliary voltage UAUX Current2 A per output6 A total (TB ≤ 40 °C)4 A total (TB ≤ 70 °C) Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 Programming instructions ProfileS-8.1 IO code8 ID code1 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 - OUT1 D1 - OUT2 D2 - OUT3 D3 - OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass200 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-4A-G12-EA2L Product Description G12 flat module4 electronic outputs (PNP) General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd230 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED OUTSwitching status (output); 4 yellow/red LEDs Yellow: output activeRed: output overload Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Output Number/Type4 electronic outputs, PNP Supplyfrom external auxiliary voltage UAUX Current2 A per output6 A total (TB ≤ 40 °C)4 A total (TB ≤ 70 °C) Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 Programming instructions ProfileS-8.1 IO code8 ID code1 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 - OUT1 D1 - OUT2 D2 - OUT3 D3 - OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass200 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Avis sur notre entreprise