VAA-4E-G2-ZA PEPPERL+FUCHS - Part number: 187746
Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

VAA-4E-G2-ZA PEPPERL+FUCHS - Part number: 187746

PEPPERL+FUCHS

AS-Interface sensor module VAA-4E-G2-ZA VAA-4E-G2-ZA AS-Interface certificate Degree of protection IP67 Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Inputs for 2- and 3-wire sensors Power supply of inputs from the module Function display for bus and inputs Monitoring of sensor overloads AS-Interface sensor module VAA-4E-G2-ZA VAA-4E-G2-ZA AS-Interface certificate Degree of protection IP67 Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Inputs for 2- and 3-wire sensors Power supply of inputs from the module Function display for bus and inputs Monitoring of sensor overloads

MPNs 187746, PEP187746, VAA-4E-G2-ZA
Code SH 85371091
Weight 0.1 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VAA-4E-G2-ZA Product Description G2 flat module4 inputs (PNP) General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor supply LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 240 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 150 mA (TB ≤ 60 °C), short-circuit protected Input current≤ 8 mA (limited internally) Switching point 0 (unattenuated)≤ 1.5 mA 1 (attenuated)≥ 4.5 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-0.1 IO code0 ID code1 ID1 codeF ID2 codeF Data bits (function via AS-Interface) input output D0 IN1 - D1 IN2 - D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass100 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-4E-G2-ZA Product Description G2 flat module4 inputs (PNP) General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor supply LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 240 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 150 mA (TB ≤ 60 °C), short-circuit protected Input current≤ 8 mA (limited internally) Switching point 0 (unattenuated)≤ 1.5 mA 1 (attenuated)≥ 4.5 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-0.1 IO code0 ID code1 ID1 codeF ID2 codeF Data bits (function via AS-Interface) input output D0 IN1 - D1 IN2 - D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass100 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Avis sur notre entreprise