AS-Interface sensor/actuator module VAA-4E4A-KE-ZEJQ/E2L VAA-4E4A-KE-ZEJQ/E2L Housing with removable, mechanical and color coded terminals Communication monitoring Inputs for 2- and 3-wire sensors Addressing jack Power supply of outputs from the external auxiliary voltage Selectable supply to the sensors: External or from the module Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs Red LED per channel, lights up in the event of output overload Switchable lead breakage detection (outputs) AS-Interface sensor/actuator module VAA-4E4A-KE-ZEJQ/E2L VAA-4E4A-KE-ZEJQ/E2L Housing with removable, mechanical and color coded terminals Communication monitoring Inputs for 2- and 3-wire sensors Addressing jack Power supply of outputs from the external auxiliary voltage Selectable supply to the sensors: External or from the module Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs Red LED per channel, lights up in the event of output overload Switchable lead breakage detection (outputs)

MPNs 209759, PEP209759, VAA-4E4A-KE-ZEJQ/E2L
Code SH 85371091
Weight 0.15 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

302,39 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VAA-4E4A-KE-ZEJQ/E2L Product Description KE switch cabinet module4 inputs and 4 outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA (without sensors) / max. 190 mA Protection classIII Surge protectionUEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) Voltage21 ... 31 V DC (INT) Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT) Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap) Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass150 g MountingDIN mounting rail Tightening torque of clamping screws0.5 Nm ... 0.6 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-4E4A-KE-ZEJQ/E2L Product Description KE switch cabinet module4 inputs and 4 outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA (without sensors) / max. 190 mA Protection classIII Surge protectionUEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) Voltage21 ... 31 V DC (INT) Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT) Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap) Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass150 g MountingDIN mounting rail Tightening torque of clamping screws0.5 Nm ... 0.6 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535