VBA-2E1A-G10-ZAL/E2L-1M-V1-Y PEPPERL+FUCHS - Part number: 267681
Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

VBA-2E1A-G10-ZAL/E2L-1M-V1-Y PEPPERL+FUCHS - Part number: 267681

PEPPERL+FUCHS

AS-Interface sensor/actuator module VBA-2E1A-G10-ZAL/E2L-1M-V1-Y VBA-2E1A-G10-ZAL/E2L-1M-V1-Y Ultra-compact enclosure Gold-plated and machined contacts One piece housing Degree of protection IP68 / IP69K Direct connection via cable outlet AS-Interface sensor/actuator module VBA-2E1A-G10-ZAL/E2L-1M-V1-Y VBA-2E1A-G10-ZAL/E2L-1M-V1-Y Ultra-compact enclosure Gold-plated and machined contacts One piece housing Degree of protection IP68 / IP69K Direct connection via cable outlet

MPNs 267681, PEP267681, VBA-2E1A-G10-ZAL/E2L-1M-V1-Y
Code SH 85371091
Weight 0.1 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Disponible sur demande

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VBA-2E1A-G10-ZAL/E2L-1M-V1-Y Product Description G10 ultra compact module2 inputs and 1 output General specifications Node typeA/B node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or overload of outputs or external auxiliary voltage UAUX missing LED AS-iAS-Interface voltage; LED green LED INswitching state (input); 2 LED yellow LED OUTSwitching state (output); LED yellow Electrical specifications Auxiliary voltage20 ... 30 V DC PELV Rated operating voltage18.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom external auxiliary voltage UAUX Voltage20 ... 30 V Current loading capacity≤ 1000 mA overload and short-circuit resistant Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type1 electronic output, PNP, Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) Current loading capacity≤ 1000 mA overload and short-circuit resistant Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007/A1:2011 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.A.E IO code7 ID codeA ID1 code7 ID2 codeE Data bits (function via AS-Interface)InputOutput D0 IN1 O1 D1 IN2 - D2 - - D3 - - Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionhousing: IP67 IP67 / IP68 / IP69K with flat cable VAZ-FK-S-* M12 socket: IP69K ConnectionAS-Interface/UAUX: AS-Interface flat cable Inputs/outputs: M12 round connector, 4-pin, A-coded, according to IEC 61076-2-101:2012 WAGO terminal type 733-105 Material ContactsM12: CuSn/Au WAGO terminal: CrNi HousingPBT PC BodyPUR, black CablePUR Mounting screwStainless steel 1.4305 / AISI 303 Cable Sheath diameter∅4,3 mm Colorblack Cores0.34 mm2 Length1 m Mass100 g Tightening torque, fastening screws1.65 Nm Tightening torque, cable gland0.4 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E1A-G10-ZAL/E2L-1M-V1-Y Product Description G10 ultra compact module2 inputs and 1 output General specifications Node typeA/B node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or overload of outputs or external auxiliary voltage UAUX missing LED AS-iAS-Interface voltage; LED green LED INswitching state (input); 2 LED yellow LED OUTSwitching state (output); LED yellow Electrical specifications Auxiliary voltage20 ... 30 V DC PELV Rated operating voltage18.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom external auxiliary voltage UAUX Voltage20 ... 30 V Current loading capacity≤ 1000 mA overload and short-circuit resistant Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type1 electronic output, PNP, Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) Current loading capacity≤ 1000 mA overload and short-circuit resistant Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007/A1:2011 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.A.E IO code7 ID codeA ID1 code7 ID2 codeE Data bits (function via AS-Interface)InputOutput D0 IN1 O1 D1 IN2 - D2 - - D3 - - Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionhousing: IP67 IP67 / IP68 / IP69K with flat cable VAZ-FK-S-* M12 socket: IP69K ConnectionAS-Interface/UAUX: AS-Interface flat cable Inputs/outputs: M12 round connector, 4-pin, A-coded, according to IEC 61076-2-101:2012 WAGO terminal type 733-105 Material ContactsM12: CuSn/Au WAGO terminal: CrNi HousingPBT PC BodyPUR, black CablePUR Mounting screwStainless steel 1.4305 / AISI 303 Cable Sheath diameter∅4,3 mm Colorblack Cores0.34 mm2 Length1 m Mass100 g Tightening torque, fastening screws1.65 Nm Tightening torque, cable gland0.4 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Avis sur notre entreprise