VBA-4E4A-CB1-ZEJ/E2J PEPPERL+FUCHS - Part number: 203158
Rupture de stock - Backorder
A commander auprès du fabricant
252,54 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

VBA-4E4A-CB1-ZEJ/E2J PEPPERL+FUCHS - Part number: 203158

PEPPERL+FUCHS

AS-Interface printed circuit board module VBA-4E4A-CB1-ZEJ/E2J VBA-4E4A-CB1-ZEJ/E2J Integrated communication monitoring function Inputs and outputs short-circuit and overload proof Supply of the inputs and the outputs from AS-Interface Function display for bus, inputs and outputs Connection via removable screw terminals AS-Interface printed circuit board module VBA-4E4A-CB1-ZEJ/E2J VBA-4E4A-CB1-ZEJ/E2J Integrated communication monitoring function Inputs and outputs short-circuit and overload proof Supply of the inputs and the outputs from AS-Interface Function display for bus, inputs and outputs Connection via removable screw terminals

MPNs 203158, PEP203158, VBA-4E4A-CB1-ZEJ/E2J
Code SH 85371091
Weight N/A

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

252,54 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

Datasheet excerpt: Technical data of  VBA-4E4A-CB1-ZEJ/E2J Product Description Printed circuit board module4 inputs/4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specificationV3.0 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 180 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Input current5 mA (typically) Switching pointaccording to EN 61131-2 Typ 1 0 (unattenuated)≤ 0.5 mA 1 (attenuated)≥ 2 mA Signal delay< 2 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP Supplyfrom AS-Interface Voltage21 ... 31 V Current≤ 100 mA per output, ≤ 140 mA total Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 50295:1999, IEC 62026-2:2015 InputEN 61131-2:2015 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61326-1:2013 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree2 Mechanical specifications Connectionscrew terminals, removable rated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2In case of wire end ferrule with plastic sleeve: 0.25 mm2 ... 0.5 mm2On connection of multiple conductors when using two conductors with the same cross section:Flexible with twin wire end ferrule: Mass90 g Tightening torque of clamping screws0.22 ... 0.25 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E4A-CB1-ZEJ/E2J Product Description Printed circuit board module4 inputs/4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specificationV3.0 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 180 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Input current5 mA (typically) Switching pointaccording to EN 61131-2 Typ 1 0 (unattenuated)≤ 0.5 mA 1 (attenuated)≥ 2 mA Signal delay< 2 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP Supplyfrom AS-Interface Voltage21 ... 31 V Current≤ 100 mA per output, ≤ 140 mA total Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 50295:1999, IEC 62026-2:2015 InputEN 61131-2:2015 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61326-1:2013 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree2 Mechanical specifications Connectionscrew terminals, removable rated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2In case of wire end ferrule with plastic sleeve: 0.25 mm2 ... 0.5 mm2On connection of multiple conductors when using two conductors with the same cross section:Flexible with twin wire end ferrule: Mass90 g Tightening torque of clamping screws0.22 ... 0.25 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535