NCB40-FP-N0-P4 PEPPERL+FUCHS - Part number: 70133126
Rupture de stock - Backorder
A commander auprès du fabricant
349,21 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

NCB40-FP-N0-P4 PEPPERL+FUCHS - Part number: 70133126

PEPPERL+FUCHS

Inductive sensor NCB40-FP-N0-P4 NCB40-FP-N0-P4 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCB40-FP-N0-P4 NCB40-FP-N0-P4 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70133126, PEP70133126, NCB40-FP-N0-P4
Code SH 85365090
Weight N/A

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

349,21 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  NCB40-FP-N0-P4 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance40 mm Installationflush Assured operating distance0 ... 32 mm Actual operating distance36 ... 44 mm typ. 40 mm Reduction factor rAl 0.35 Reduction factor rCu 0.35 Reduction factor r304 0.8 Output type2-wire Nominal ratings Installation conditions F100 mm Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 80 Hz Hysteresis0 ... 5 typ. 3 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Time delay before availability≤ 20 ms Switching state indicatorLED, yellow Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X EAC conformityTR CU 012/2011 UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002304 NEPSI approval NEPSI certificateGYJ16.1394X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typescrew terminals Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % Core cross sectionup to 2.5 mm2 Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 Housing materialPBT/metal Sensing facePBT Housing basealuminum painted Degree of protectionIP67 NoteTightening torque: 1.8 Nm (housing) General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCB40-FP-N0-P4 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance40 mm Installationflush Assured operating distance0 ... 32 mm Actual operating distance36 ... 44 mm typ. 40 mm Reduction factor rAl 0.35 Reduction factor rCu 0.35 Reduction factor r304 0.8 Output type2-wire Nominal ratings Installation conditions F100 mm Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 80 Hz Hysteresis0 ... 5 typ. 3 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Time delay before availability≤ 20 ms Switching state indicatorLED, yellow Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X EAC conformityTR CU 012/2011 UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002304 NEPSI approval NEPSI certificateGYJ16.1394X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typescrew terminals Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % Core cross sectionup to 2.5 mm2 Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 Housing materialPBT/metal Sensing facePBT Housing basealuminum painted Degree of protectionIP67 NoteTightening torque: 1.8 Nm (housing) General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

Avis sur notre entreprise