PEPPERL+FUCHS

Inductive sensor PL2-F25-N4-K PL2-F25-N4-K For installation in housing PL2... without valve connection ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor PL2-F25-N4-K PL2-F25-N4-K For installation in housing PL2... without valve connection ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 291802, PEP291802, PL2-F25-N4-K
Code SH 85365090
Weight N/A

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

149,41 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
To États-Unis starting from 27,36 USD par DHL Express Worldwide
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Informations sur les produits

La description

Datasheet excerpt: Technical data of  PL2-F25-N4-K General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.43 mm Actual operating distance2.7 ... 3.3 mm Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 100 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Time delay before availability≤ 1 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd834 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X CCC approval Hazardous Location2020322315002262 NEPSI approval NEPSI certificateGYJ19.1410X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)Cage tension spring terminals Core cross section (system side)up to 2.5 mm2 Housing materialPBT Sensing facePBT Mass79 g Tightening torque, fastening screws0.3 Nm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  PL2-F25-N4-K General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.43 mm Actual operating distance2.7 ... 3.3 mm Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 100 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Time delay before availability≤ 1 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd834 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X CCC approval Hazardous Location2020322315002262 NEPSI approval NEPSI certificateGYJ19.1410X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)Cage tension spring terminals Core cross section (system side)up to 2.5 mm2 Housing materialPBT Sensing facePBT Mass79 g Tightening torque, fastening screws0.3 Nm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550