KC-LCDC-48-2R-230VAC PEPPERL+FUCHS - Part number: 214740
Rupture de stock - Backorder
A commander auprès du fabricant
425,17 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

KC-LCDC-48-2R-230VAC PEPPERL+FUCHS - Part number: 214740

PEPPERL+FUCHS

Timer, Counter, Tachometer KC-LCDC-48-2R-230VAC KC-LCDC-48-2R-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs Multicolor display Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only) Timer, Counter, Tachometer KC-LCDC-48-2R-230VAC KC-LCDC-48-2R-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs Multicolor display Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only)

MPNs 214740, PEP214740, KC-LCDC-48-2R-230VAC
Code SH 90262000
Weight 0.14 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

425,17 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  KC-LCDC-48-2R-230VAC Product Description LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supply20.4 ... 27.6 V DC, max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass142 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902 Datasheet excerpt: Technical data of  KC-LCDC-48-2R-230VAC Product Description LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supply20.4 ... 27.6 V DC, max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass142 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902

Avis sur notre entreprise