KC-LCDC-48-2R-24VDC PEPPERL+FUCHS - Part number: 214741
Rupture de stock - Backorder
A commander auprès du fabricant
382,67 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client

KC-LCDC-48-2R-24VDC PEPPERL+FUCHS - Part number: 214741

PEPPERL+FUCHS

Thru-beam sensor OBE25M-R200-S2EP-IO OBE25M-R200-S2EP-IO Medium design with versatile mounting options IO-link interface for service and process data Various frequencies for avoiding mutual interference (cross-talk immunity) Extended temperature range-40°C ... 60°C High degree of protection IP69K Thru-beam sensor OBE25M-R200-S2EP-IO OBE25M-R200-S2EP-IO Medium design with versatile mounting options IO-link interface for service and process data Various frequencies for avoiding mutual interference (cross-talk immunity) Extended temperature range-40°C ... 60°C High degree of protection IP69K

MPNs 214741, PEP214741, KC-LCDC-48-2R-24VDC
Code SH 90262000
Weight 0.14 kg

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

382,67 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  KC-LCDC-48-2R-24VDC Product Description LCD batch controller with 2 relay outputs and 24 VDC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing10 … 30 V DC: T 0.2 A Operating voltage10 ... 30 V DC Power consumptionmax. 1.5 W Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High0.6 x Ue ... 30 V DC Low0 ... 0.2 x Ue Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supplyconnected power supply is looped through,max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 61000-6-2:2005 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Mechanical specifications Degree of protectionIP65 (front) Mass138 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902 Datasheet excerpt: Technical data of  KC-LCDC-48-2R-24VDC Product Description LCD batch controller with 2 relay outputs and 24 VDC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing10 … 30 V DC: T 0.2 A Operating voltage10 ... 30 V DC Power consumptionmax. 1.5 W Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High0.6 x Ue ... 30 V DC Low0 ... 0.2 x Ue Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supplyconnected power supply is looped through,max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 61000-6-2:2005 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Mechanical specifications Degree of protectionIP65 (front) Mass138 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902

Avis sur notre entreprise