Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec. Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec.

MPNs 190149, PEP190149, KFU8-DW-1.D
Weight N/A

L’image du produit est à des fins d’illustration seulement.
Le pays d’origine, le code SH et la description sont fournis par le fabricant et peuvent être modifiés sans préavis. Pour cette raison, PLC-City ne peut être tenu responsable des écarts éventuels.
Vendu par PLC-CITY® et expédié d’Italie

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

619,71 USD

Taxes d’importation exclues

Vous devez être connecté à votre compte client
Vendu par PLC-CITY® et expédié d’Italie
Nous sommes un partenaire spécialisé de PEPPERL+FUCHS
Livraison express gratuite vers États-Unis
Loader...
Voir tous les services d’expédition
Demander un devis pour connaître la date de livraison

Nous acceptons de nombreuses méthodes de paiement : Virement bancaire (SEPA, ACH), Cartes de débit/crédit (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, lien par Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WhateCay.
Plus d’informations sur nos méthodes de paiement

Ce produit est couvert par une garantie 12 Mois, valable pour les défauts de fabrication ou les dysfonctionnements. La garantie ne couvre pas les dommages causés par une mauvaise utilisation ou des dommages accidentels.
En savoir plus sur notre garantie

Les retours doivent être préalablement autorisés et donnent lieu à un avoir. Les articles en commande différée sont exclus.

Voir notre politique de retour

Obtenez votre devis personnalisé maintenant

Un représentant des ventes dédié vous aidera à offrir le meilleur prix et les meilleurs délais de livraison.

Vous devez être connecté à votre compte client

Demandez votre service technique sur mesure

Comptez sur notre équipe technique d’experts pour une gamme de services personnalisés: réparation, programmation, maintenance et bien plus encore.

Informations sur les produits

La description

Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007