VBG-PBS-K30-DMD PEPPERL+FUCHS - Part number: 220392
Non disponibile - Backorder
Da ordinare dal produttore
4.795,00 USD

Tasse di importazione escluse

Devi essere autenticato

VBG-PBS-K30-DMD PEPPERL+FUCHS - Part number: 220392

PEPPERL+FUCHS

AS-Interface Gateway/Safety Monitor VBG-PBS-K30-DMD VBG-PBS-K30-DMD Gateway and safety monitor in one housing Gateway compliant with AS-Interface specification 3.0 Connection to PROFIBUS DP AS-Interface safety monitor with extended range of functions Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 Memory card for configuration data 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs PROFIsafe protocol for centralized and secure higher-level control AS-Interface Gateway/Safety Monitor VBG-PBS-K30-DMD VBG-PBS-K30-DMD Gateway and safety monitor in one housing Gateway compliant with AS-Interface specification 3.0 Connection to PROFIBUS DP AS-Interface safety monitor with extended range of functions Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 Memory card for configuration data 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs PROFIsafe protocol for centralized and secure higher-level control

MPNs 220392, PEP220392, VBG-PBS-K30-DMD
Codice HS 85176900
Peso 0.8 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

4.795,00 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  VBG-PBS-K30-DMD Product Description PROFIBUS Gateway, PROFIsafe for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Switch-on delay< 10 s UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED PROFIBUSPROFIBUS master detected; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartInput closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Electrical specifications Insulation voltage≥ 500 V Rated operating voltage26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Rated operating current≤ 300 mA off AS interface network 1≤ 300 mA off AS interface network 2≤ 370 mA in total Interface 1 Interface typeRS-485 ProtocolPROFIBUS according to DIN 19245 Part 3 Transfer rate9.6 kBit/s / 12 MBit/s , Automatic baud rate detection Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection PROFIBUSSub-D interface AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 Fieldbus standardPROFIBUS according to DIN 19245 Part 3 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004 Datasheet excerpt: Technical data of  VBG-PBS-K30-DMD Product Description PROFIBUS Gateway, PROFIsafe for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Switch-on delay< 10 s UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED PROFIBUSPROFIBUS master detected; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartInput closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Electrical specifications Insulation voltage≥ 500 V Rated operating voltage26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Rated operating current≤ 300 mA off AS interface network 1≤ 300 mA off AS interface network 2≤ 370 mA in total Interface 1 Interface typeRS-485 ProtocolPROFIBUS according to DIN 19245 Part 3 Transfer rate9.6 kBit/s / 12 MBit/s , Automatic baud rate detection Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection PROFIBUSSub-D interface AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 Fieldbus standardPROFIBUS according to DIN 19245 Part 3 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004