VBG-PN-K20-D-BV PEPPERL+FUCHS - Part number: 261676
Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

VBG-PN-K20-D-BV PEPPERL+FUCHS - Part number: 261676

PEPPERL+FUCHS

AS-Interface gateway VBG-PN-K20-D-BV VBG-PN-K20-D-BV Gateway compliant with AS-Interface specification 3.0 Connection to PROFINET IO Earth fault detection Fault diagnosis via LEDs and grafic display Compact stainless steel housing AS-Interface gateway VBG-PN-K20-D-BV VBG-PN-K20-D-BV Gateway compliant with AS-Interface specification 3.0 Connection to PROFINET IO Earth fault detection Fault diagnosis via LEDs and grafic display Compact stainless steel housing

MPNs 261676, PEP261676, VBG-PN-K20-D-BV
Codice HS 85176900
Peso 0.46 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  VBG-PN-K20-D-BV Product Description PROFINET Gateway General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters MTTFd105 a at 30 °C Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface Interface 1 Interface typePROFINET I / O device (IRT) Physical 2 x RJ-45 ProtocolMedia Redundancy Protocol (MRP) Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeChip card slot Connection PROFINETRJ-45 AS-Interfaceremovable spring clamp terminals Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass460 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBG-PN-K20-D-BV Product Description PROFINET Gateway General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters MTTFd105 a at 30 °C Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface Interface 1 Interface typePROFINET I / O device (IRT) Physical 2 x RJ-45 ProtocolMedia Redundancy Protocol (MRP) Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeChip card slot Connection PROFINETRJ-45 AS-Interfaceremovable spring clamp terminals Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass460 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535