AS-Interface safety module VAA-2E-KE1-S VAA-2E-KE1-S 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch Housing with removable terminals Communication monitoring Power supply of inputs from the module Function display for bus and inputs Cross-circuit detection Addressing jack AS-Interface safety module VAA-2E-KE1-S VAA-2E-KE1-S 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch Housing with removable terminals Communication monitoring Power supply of inputs from the module Function display for bus and inputs Cross-circuit detection Addressing jack

MPNs 134088, PEP134088, VAA-2E-KE1-S
Codice HS 85371091
Peso N/A

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

261,00 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  VAA-2E-KE1-S Product Description KE1 safety module for the control cabinet, 2 Safety-related inputs General specifications Node typeSafety node AS-Interface specificationV2.11 Required gateway specification≥ V2.0 ProfileS-0.B IO code0 ID codeB ID1 codeF ID2 code0 UL File NumberE87056 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 / PL e MTTFd200 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0 LED PWRAS-Interface voltage; LED green LED INswitching state (input); 2 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V PELV from AS-Interface Rated operating current≤ 70 mA Protection classIII Input Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored: 2 single-channel contacts: up to category 2 / PL c according to EN ISO 13849-1 or 1 two-channel contact: up to category 4 / PL e according to EN ISO 13849-1 Cable length must not exceed 300 m per input. Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 Standard conformity Insulation coordinationEN 50178:1998 Electromagnetic compatibilityEN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4 Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013+A1:2019 Electrical safetyEN 50178:1998 IEC 60204-1:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Functional safetyCategory 4 / PL e to EN ISO 13849-1:2015 SIL 3 according to IEC 62061:2015 and IEC 61508 Part 1-7:2010 StandardsNFPA 79:2002 Ambient conditions Ambient temperature-25 ... 50 °C (-13 ... 122 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionIP20 Connectionremovable terminals, terminal connection ≤ 2.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-2E-KE1-S Product Description KE1 safety module for the control cabinet, 2 Safety-related inputs General specifications Node typeSafety node AS-Interface specificationV2.11 Required gateway specification≥ V2.0 ProfileS-0.B IO code0 ID codeB ID1 codeF ID2 code0 UL File NumberE87056 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 / PL e MTTFd200 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0 LED PWRAS-Interface voltage; LED green LED INswitching state (input); 2 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V PELV from AS-Interface Rated operating current≤ 70 mA Protection classIII Input Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored: 2 single-channel contacts: up to category 2 / PL c according to EN ISO 13849-1 or 1 two-channel contact: up to category 4 / PL e according to EN ISO 13849-1 Cable length must not exceed 300 m per input. Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 Standard conformity Insulation coordinationEN 50178:1998 Electromagnetic compatibilityEN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4 Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013+A1:2019 Electrical safetyEN 50178:1998 IEC 60204-1:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Functional safetyCategory 4 / PL e to EN ISO 13849-1:2015 SIL 3 according to IEC 62061:2015 and IEC 61508 Part 1-7:2010 StandardsNFPA 79:2002 Ambient conditions Ambient temperature-25 ... 50 °C (-13 ... 122 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionIP20 Connectionremovable terminals, terminal connection ≤ 2.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535