VAA-4E4A-G4-ZE/E2 PEPPERL+FUCHS - Part number: 188589
Non disponibile - Backorder
Da ordinare dal produttore
380,89 USD

Tasse di importazione escluse

Devi essere autenticato

VAA-4E4A-G4-ZE/E2 PEPPERL+FUCHS - Part number: 188589

PEPPERL+FUCHS

AS-Interface sensor/actuator module VAA-4E4A-G4-ZE/E2 VAA-4E4A-G4-ZE/E2 Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Communication monitoring, turn-off Inputs for 2- and 3-wire sensors Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs Monitoring of sensor overloads AS-Interface sensor/actuator module VAA-4E4A-G4-ZE/E2 VAA-4E4A-G4-ZE/E2 Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Communication monitoring, turn-off Inputs for 2- and 3-wire sensors Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs Monitoring of sensor overloads

MPNs 188589, PEP188589, VAA-4E4A-G4-ZE/E2
Codice HS 85371091
Peso 0.35 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

380,89 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  VAA-4E4A-G4-ZE/E2 Product Description G4 module IP654 inputs (PNP) and 4 electronic outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd150 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULTdual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply or outputs LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 230 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 160 mA (TB ≤ 60 °C), short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current1 A per output, 4 A total Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals Material HousingPA 6 GF30 Mass350 g Tightening torque, housing screws0.8 Nm MountingDIN rail or screw mounting Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-4E4A-G4-ZE/E2 Product Description G4 module IP654 inputs (PNP) and 4 electronic outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd150 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULTdual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply or outputs LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 230 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 160 mA (TB ≤ 60 °C), short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current1 A per output, 4 A total Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals Material HousingPA 6 GF30 Mass350 g Tightening torque, housing screws0.8 Nm MountingDIN rail or screw mounting Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535