VBA-4E-G2-ZA PEPPERL+FUCHS - Part number: 115086
Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

VBA-4E-G2-ZA PEPPERL+FUCHS - Part number: 115086

PEPPERL+FUCHS

AS-Interface sensor module VBA-4E-G2-ZA VBA-4E-G2-ZA AS-Interface certificate Degree of protection IP67 A/B node with extended addressing possibility for up to 62 nodes Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring Inputs for 2-, 3-, and 4-wire sensors Supply for inputs from AS-Interface Ground connection (FE) possible Function display for bus and inputs Detection of overload on sensor supply AS-Interface sensor module VBA-4E-G2-ZA VBA-4E-G2-ZA AS-Interface certificate Degree of protection IP67 A/B node with extended addressing possibility for up to 62 nodes Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring Inputs for 2-, 3-, and 4-wire sensors Supply for inputs from AS-Interface Ground connection (FE) possible Function display for bus and inputs Detection of overload on sensor supply

MPNs 115086, PEP115086, VBA-4E-G2-ZA
Codice HS 85371091
Peso 0.1 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  VBA-4E-G2-ZA Product Description G2 flat module4 inputs (PNP) General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.0 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor supply LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 240 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 150 mA (TB ≤ 60 °C), overload-proof and short-circuit protected Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-0.A.2 IO code0 ID codeA ID1 code7 ID2 code2 Data bits (function via AS-Interface)InputOutput D0 IN1 - D1 IN2 - D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass100 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E-G2-ZA Product Description G2 flat module4 inputs (PNP) General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.0 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor supply LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 240 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA (TB ≤ 40 °C),≤ 150 mA (TB ≤ 60 °C), overload-proof and short-circuit protected Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-0.A.2 IO code0 ID codeA ID1 code7 ID2 code2 Data bits (function via AS-Interface)InputOutput D0 IN1 - D1 IN2 - D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass100 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Le recensioni dei nostri clienti