VBA-4E4E-G12-ZAJ PEPPERL+FUCHS - Part number: 200524
Non disponibile - Backorder
Da ordinare dal produttore
373,07 USD

Tasse di importazione escluse

Devi essere autenticato

VBA-4E4E-G12-ZAJ PEPPERL+FUCHS - Part number: 200524

PEPPERL+FUCHS

AS-Interface sensor module VBA-4E4E-G12-ZAJ VBA-4E4E-G12-ZAJ A/B node with extended addressing possibility for up to 62 nodes One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring, configurable Inputs for 2-, 3-, and 4-wire sensors DIN rail mounting AS-Interface certificate Automatic addressing with latest masters in the event of replacement AS-Interface sensor module VBA-4E4E-G12-ZAJ VBA-4E4E-G12-ZAJ A/B node with extended addressing possibility for up to 62 nodes One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring, configurable Inputs for 2-, 3-, and 4-wire sensors DIN rail mounting AS-Interface certificate Automatic addressing with latest masters in the event of replacement

MPNs 200524, PEP200524, VBA-4E4E-G12-ZAJ
Codice HS 85371091
Peso 0.23 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

373,07 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  VBA-4E4E-G12-ZAJ Product Description G12 flat module2 x 4 inputs (PNP) General specifications Node typeDouble A/B slave AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd60 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULT2 Dual LEDs green/redgreen: AS-Interface voltagered: Communication erroryellow/red flashing: Address 0green/red flashing: Sensor supply overload LED INswitching state (input); 8 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA (without sensors) / max. 280 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Input Number/Type2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA, overload and short-circuit protected Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 6 mA Signal delay< 1 ms (input/AS-Interface) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-0.A.2 IO code0 ID codeA ID1 codeSlave 1 Slave 21 2 ID2 code2 Data bits (function via AS-Interface)Input slave 1 input slave 2 D0IN1.1 IN2.1 D1IN1.2 IN2.2 D2IN1.3 IN2.3 D3IN1.4 IN2.4 Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass230 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E4E-G12-ZAJ Product Description G12 flat module2 x 4 inputs (PNP) General specifications Node typeDouble A/B slave AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd60 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULT2 Dual LEDs green/redgreen: AS-Interface voltagered: Communication erroryellow/red flashing: Address 0green/red flashing: Sensor supply overload LED INswitching state (input); 8 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA (without sensors) / max. 280 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Input Number/Type2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA, overload and short-circuit protected Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 6 mA Signal delay< 1 ms (input/AS-Interface) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-0.A.2 IO code0 ID codeA ID1 codeSlave 1 Slave 21 2 ID2 code2 Data bits (function via AS-Interface)Input slave 1 input slave 2 D0IN1.1 IN2.1 D1IN1.2 IN2.2 D2IN1.3 IN2.3 D3IN1.4 IN2.4 Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass230 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Le recensioni dei nostri clienti