OBT30-R2-E2-L PEPPERL+FUCHS - Part number: 282023
Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

OBT30-R2-E2-L PEPPERL+FUCHS - Part number: 282023

PEPPERL+FUCHS

Laser triangulation sensor with background suppression OBT30-R2-E2-L OBT30-R2-E2-L Ultra-small housing design DuraBeam Laser Sensors - durable and employable like an LED 45° cable outlet for maximum mounting freedom under extremely tight space constraints Improvement in machine availability with abrasion-resistant, antistatic glass front Precision object detection, almost irrespective of the color Laser triangulation sensor with background suppression OBT30-R2-E2-L OBT30-R2-E2-L Ultra-small housing design DuraBeam Laser Sensors - durable and employable like an LED 45° cable outlet for maximum mounting freedom under extremely tight space constraints Improvement in machine availability with abrasion-resistant, antistatic glass front Precision object detection, almost irrespective of the color

MPNs 282023, PEP282023, OBT30-R2-E2-L
Codice HS 85365000
Peso N/A

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  OBT30-R2-E2-L Product Description Laser triangulation sensor with background suppression, ultra-small design with M2 mounting, 30 mm sensing range, PNP output, 2 m fixed cable General specifications Detection range7 ... 30 mm Reference targetstandard white, 100 mm x 100 mm Light sourcelaser diode Light typemodulated visible red light , 680 nm Laser nominal ratings NoteLASER LIGHT , DO NOT STARE INTO BEAM Laser class1 Wave length680 nm Beam divergence> 5 mrad Pulse length3 µs Repetition rate16.6 kHz max. pulse energy9.5 nJ Black-white difference (6 %/90 %)< 5 % at 30 mm Diameter of the light spot< 1 mm at a distance of 30 mm Opening angle2 ° Optical facefrontal Ambient light limitEN 60947-5-2 : 30000 Lux Functional safety related parameters MTTFd800 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: Power on flashing: Short circuit/overload indication Function indicatorLED yellow ON: lights when object is detected Electrical specifications Operating voltage12 ... 24 V No-load supply current< 10 mA Protection classIII Output Switching typeNO contact Signal output1 PNP output, short-circuit protected, reverse polarity protected, open collector Switching voltagemax. 30 V DC Switching currentmax. 50 mA , resistive load Voltage drop≤ 1.5 V DC Switching frequency2 kHz Response time250 µs Conformity Product standardEN 60947-5-2 Laser safetyEN 60825-1:2007 Approvals and certificates EAC conformityTR CU 020/2011 CCC approvalCCC approval / marking not required for products rated ≤36 V FDA approvalIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Storage temperature-30 ... 70 °C (-22 ... 158 °F) Mechanical specifications Housing width7.5 mm Housing height24 mm Housing depth11.2 mm Degree of protectionIP67 Connection2 m fixed cable Material HousingPC/ABS and TPU Optical faceglass CablePUR InstallationFixing screws , 2 x M2 allen head screws included with delivery Mass20 g Cable length2 m Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  OBT30-R2-E2-L Product Description Laser triangulation sensor with background suppression, ultra-small design with M2 mounting, 30 mm sensing range, PNP output, 2 m fixed cable General specifications Detection range7 ... 30 mm Reference targetstandard white, 100 mm x 100 mm Light sourcelaser diode Light typemodulated visible red light , 680 nm Laser nominal ratings NoteLASER LIGHT , DO NOT STARE INTO BEAM Laser class1 Wave length680 nm Beam divergence> 5 mrad Pulse length3 µs Repetition rate16.6 kHz max. pulse energy9.5 nJ Black-white difference (6 %/90 %)< 5 % at 30 mm Diameter of the light spot< 1 mm at a distance of 30 mm Opening angle2 ° Optical facefrontal Ambient light limitEN 60947-5-2 : 30000 Lux Functional safety related parameters MTTFd800 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: Power on flashing: Short circuit/overload indication Function indicatorLED yellow ON: lights when object is detected Electrical specifications Operating voltage12 ... 24 V No-load supply current< 10 mA Protection classIII Output Switching typeNO contact Signal output1 PNP output, short-circuit protected, reverse polarity protected, open collector Switching voltagemax. 30 V DC Switching currentmax. 50 mA , resistive load Voltage drop≤ 1.5 V DC Switching frequency2 kHz Response time250 µs Conformity Product standardEN 60947-5-2 Laser safetyEN 60825-1:2007 Approvals and certificates EAC conformityTR CU 020/2011 CCC approvalCCC approval / marking not required for products rated ≤36 V FDA approvalIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Storage temperature-30 ... 70 °C (-22 ... 158 °F) Mechanical specifications Housing width7.5 mm Housing height24 mm Housing depth11.2 mm Degree of protectionIP67 Connection2 m fixed cable Material HousingPC/ABS and TPU Optical faceglass CablePUR InstallationFixing screws , 2 x M2 allen head screws included with delivery Mass20 g Cable length2 m Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528