NCB40-FP-N0-P1-V1 PEPPERL+FUCHS - Part number: 70133125
Non disponibile - Backorder
Da ordinare dal produttore
352,41 USD

Tasse di importazione escluse

Devi essere autenticato

NCB40-FP-N0-P1-V1 PEPPERL+FUCHS - Part number: 70133125

PEPPERL+FUCHS

Inductive sensor NCB40-FP-N0-P1-V1 NCB40-FP-N0-P1-V1 40 mm flush NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCB40-FP-N0-P1-V1 NCB40-FP-N0-P1-V1 40 mm flush NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70133125, PEP70133125, NCB40-FP-N0-P1-V1
Codice HS 85365090
Peso N/A

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

352,41 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  NCB40-FP-N0-P1-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance40 mm Installationflush Assured operating distance0 ... 32 mm Actual operating distance36 ... 44 mm typ. 40 mm Reduction factor rAl 0.35 Reduction factor rCu 0.35 Reduction factor r304 0.8 Output type2-wire Nominal ratings Installation conditions F100 mm Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 80 Hz Hysteresis0 ... 5 typ. 3 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Time delay before availability≤ 20 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd2368 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X EAC conformityTR CU 012/2011 UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002304 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typeConnector plug Housing materialPBT Sensing facePBT Housing basePBT Degree of protectionIP67 Connector ThreadingM12 x 1 Number of pins4 General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCB40-FP-N0-P1-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance40 mm Installationflush Assured operating distance0 ... 32 mm Actual operating distance36 ... 44 mm typ. 40 mm Reduction factor rAl 0.35 Reduction factor rCu 0.35 Reduction factor r304 0.8 Output type2-wire Nominal ratings Installation conditions F100 mm Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 80 Hz Hysteresis0 ... 5 typ. 3 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Time delay before availability≤ 20 ms Switching state indicatorLED, yellow Functional safety related parameters MTTFd2368 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X EAC conformityTR CU 012/2011 UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002304 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typeConnector plug Housing materialPBT Sensing facePBT Housing basePBT Degree of protectionIP67 Connector ThreadingM12 x 1 Number of pins4 General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

Le recensioni dei nostri clienti