NCB8-18GM70-N0-20M-V1 PEPPERL+FUCHS - Part number: 70129545
Non disponibile - Backorder
Da ordinare dal produttore
294,71 USD

Tasse di importazione escluse

Devi essere autenticato

NCB8-18GM70-N0-20M-V1 PEPPERL+FUCHS - Part number: 70129545

PEPPERL+FUCHS

Inductive sensor NCB8-18GM70-N0-20M-V1 NCB8-18GM70-N0-20M-V1 8 mm flush Cable with M12 plug NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCB8-18GM70-N0-20M-V1 NCB8-18GM70-N0-20M-V1 8 mm flush Cable with M12 plug NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70129545, PEP70129545, NCB8-18GM70-N0-20M-V1
Codice HS 85365090
Peso N/A

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

294,71 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  NCB8-18GM70-N0-20M-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance8 mm Installationflush Assured operating distance0 ... 6.48 mm Actual operating distance7.2 ... 8.8 mm typ. 8 mm Reduction factor rAl 0.39 Reduction factor rCu 0.36 Reduction factor r304 0.71 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 1500 Hz Hysteresis1 ... 15 typ. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detectedmin. 2.2 mA Measuring plate detected≤ 1 mA Switching state indicatorall direction LED, yellow Functional safety related parameters MTTFd2660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0037X Equipment protection level GbIECEx PTB 11.0037X Equipment protection level DaIECEx PTB 11.0037X Equipment protection level MbIECEx PTB 11.0037X ATEX approval Equipment protection level GaPTB 00 ATEX 2048 X Equipment protection level GbPTB 00 ATEX 2048 X Equipment protection level DaPTB 00 ATEX 2048 X UL approvalcULus Listed, General Purpose, Class 2 Power Source Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0452 CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typefixed cable with plug Housing materialStainless steel 1.4305 / AISI 303 Sensing facePBT Degree of protectionIP67 ConnectorM12 x 1 Cable Cable diameter4.8 mm ± 0.2 mm Bending radius> 10 x cable diameter Core cross section0.34 mm2 Length20 m General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 Datasheet excerpt: Technical data of  NCB8-18GM70-N0-20M-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance8 mm Installationflush Assured operating distance0 ... 6.48 mm Actual operating distance7.2 ... 8.8 mm typ. 8 mm Reduction factor rAl 0.39 Reduction factor rCu 0.36 Reduction factor r304 0.71 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 1500 Hz Hysteresis1 ... 15 typ. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detectedmin. 2.2 mA Measuring plate detected≤ 1 mA Switching state indicatorall direction LED, yellow Functional safety related parameters MTTFd2660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0037X Equipment protection level GbIECEx PTB 11.0037X Equipment protection level DaIECEx PTB 11.0037X Equipment protection level MbIECEx PTB 11.0037X ATEX approval Equipment protection level GaPTB 00 ATEX 2048 X Equipment protection level GbPTB 00 ATEX 2048 X Equipment protection level DaPTB 00 ATEX 2048 X UL approvalcULus Listed, General Purpose, Class 2 Power Source Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0452 CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typefixed cable with plug Housing materialStainless steel 1.4305 / AISI 303 Sensing facePBT Degree of protectionIP67 ConnectorM12 x 1 Cable Cable diameter4.8 mm ± 0.2 mm Bending radius> 10 x cable diameter Core cross section0.34 mm2 Length20 m General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714

Le recensioni dei nostri clienti