Inductive sensor PL3-F25-N4-S PL3-F25-N4-S For installation in housing PL3... with valve and screen connection ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor PL3-F25-N4-S PL3-F25-N4-S For installation in housing PL3... with valve and screen connection ATEX & IECEX certifications NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 291800, PEP291800, PL3-F25-N4-S
Codice HS 85365090
Peso N/A

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

149,41 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Verso Stati Uniti a partire da 27,36 USD da DHL Express Worldwide
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  PL3-F25-N4-S General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.43 mm Actual operating distance2.6 ... 2.6 mm typ. Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 100 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Time delay before availability≤ 1 ms Switching state indicatorLED, yellow Valve status indicatorLED, yellowcan be switched off by of DB1 Functional safety related parameters MTTFd834 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X CCC approval Hazardous Location2020322315002262 NEPSI approval NEPSI certificateGYJ19.1410X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)screw terminals Core cross section (system side)up to 2.5 mm2 Connection (valve side)screw terminals Core cross section (valve side)up to 2.5 mm2 Housing materialPBT Sensing facePBT Mass91 g Tightening torque, fastening screws0.3 Nm NoteInstallation in housing General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  PL3-F25-N4-S General specifications Switching function2 x normally closed (NC) Output typeNAMUR Rated operating distance3 mm Installationflush mountable Assured operating distance0 ... 2.43 mm Actual operating distance2.6 ... 2.6 mm typ. Reduction factor rAl 0.52 Reduction factor rCu 0.43 Reduction factor r304 0.86 Reduction factor rSt37 1 Reduction factor rBrass 0.54 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 100 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Time delay before availability≤ 1 ms Switching state indicatorLED, yellow Valve status indicatorLED, yellowcan be switched off by of DB1 Functional safety related parameters MTTFd834 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx TUN 17.0021X Equipment protection level GbIECEx TUN 17.0021X Equipment protection level MbIECEx TUN 17.0021X ATEX approval Equipment protection level GaTÜV 99 ATEX 1479 X Equipment protection level GbTÜV 99 ATEX 1479 X Equipment protection level Gc (ic)PF13CERT2895 X CCC approval Hazardous Location2020322315002262 NEPSI approval NEPSI certificateGYJ19.1410X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection (system side)screw terminals Core cross section (system side)up to 2.5 mm2 Connection (valve side)screw terminals Core cross section (valve side)up to 2.5 mm2 Housing materialPBT Sensing facePBT Mass91 g Tightening torque, fastening screws0.3 Nm NoteInstallation in housing General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027220501 ECLASS 10.0.127220501 ECLASS 9.027220501 ECLASS 8.027220501 ECLASS 5.127220501 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

Le recensioni dei nostri clienti