SJ3,5-N-K37 PEPPERL+FUCHS - Part number: 70132990
Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

SJ3,5-N-K37 PEPPERL+FUCHS - Part number: 70132990

PEPPERL+FUCHS

Inductive slot sensor SJ3,5-N-K37 SJ3,5-N-K37 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive slot sensor SJ3,5-N-K37 SJ3,5-N-K37 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70132990, PEP70132990, SJ3,5-N-K37
Codice HS 85365090
Peso N/A

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Disponibile su richiesta

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  SJ3,5-N-K37 General specifications Switching functionNormally closed (NC) Output typeNAMUR Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 3000 Hz Hysteresis0.41 ... 0.6 mm Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Functional safety related parameters MTTFd5270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0091X Equipment protection level DaIECEx PTB 11.0091X Equipment protection level MbIECEx PTB 11.0091X ATEX approval Equipment protection level GbPTB 99 ATEX 2219 X Equipment protection level DaPTB 99 ATEX 2219 X UL approvalcULus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 Datasheet excerpt: Technical data of  SJ3,5-N-K37 General specifications Switching functionNormally closed (NC) Output typeNAMUR Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 3000 Hz Hysteresis0.41 ... 0.6 mm Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Functional safety related parameters MTTFd5270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0091X Equipment protection level DaIECEx PTB 11.0091X Equipment protection level MbIECEx PTB 11.0091X ATEX approval Equipment protection level GbPTB 99 ATEX 2219 X Equipment protection level DaPTB 99 ATEX 2219 X UL approvalcULus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714

Le recensioni dei nostri clienti