Ultrasonic sensor UC500-D1-3K-V7 UC500-D1-3K-V7 Specially for level monitoring in vessels Large operating voltage range10 V DC ... 253 V DC20 V AC ... 253 V AC 3 relay outputs Parameter assignment via DIP-switches Temperature compensation Cable socket included with delivery Ultrasonic sensor UC500-D1-3K-V7 UC500-D1-3K-V7 Specially for level monitoring in vessels Large operating voltage range10 V DC ... 253 V DC20 V AC ... 253 V AC 3 relay outputs Parameter assignment via DIP-switches Temperature compensation Cable socket included with delivery

MPNs 212371, PEP212371, UC500-D1-3K-V7
Codice HS 90318000
Peso 0.7 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

771,02 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  UC500-D1-3K-V7 Product Description Single head system General specifications Sensing range60 ... 550 mm Dead band0 ... 60 mm Standard target plate100 mm x 100 mm Transducer frequency380 kHz Response delay> 10 s, relay< 1 s, LEDs Indicators/operating means LED redLED 1: overfill indicationLED 4: underfill indication LED green/yellowLED 2: overfill warning and normal operation LED 3: normal operation and underfill warning DIP switchsetting of the switch points/operating modes Electrical specifications Operating voltage10 ... 253 V DC 20 ... 253 V AC , 47 ... 63 Hz No-load supply current< 30 mA with UB = 30 V DC< 110 mA at UB = 10 V DC< 25 mA at UB = 220 V AC Output Output type3 relay outputs, normally open/closed, selectable Range hysteresis20 mm Contact loading253 V AC/150V DC, 3 A (ohm. load) Life spanelectrical: 105 switching cycles with ohmic load(3 A/253 V AC or 3 A/30 V DC)minimum contact load: 100 µA/100 mV DCmechanical: 20 x 106 switching cycles Temperature influence< 4 % Fusing≤ 3 A Slow-blow fuse per output in accordance with IEC 60127-2 Sheet 5 required. Recommendation: after a short circuit, check that the device is functioning correctly. Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 Approvals and certificates EAC conformityTR CU 004/2011 TR CU 020/2011 TR CU 037/2016 CCC approvalself-declaration Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Degree of protectionIP65 ConnectionFemale connector, V7 (7-pin), 90° Wire cross section: ≤1.5 mm2 cable diameter ∅7 ... 9 mm Material Housingcover: PC housing: PBTthreaded flange: stainless steel installation connector/cable socket: PETP Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam Mass700 g NoteIn case of loss or damage, the cable socket must be replaced by an identical cable socket (type V7-W) from Pepperl+Fuchs! Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960 Datasheet excerpt: Technical data of  UC500-D1-3K-V7 Product Description Single head system General specifications Sensing range60 ... 550 mm Dead band0 ... 60 mm Standard target plate100 mm x 100 mm Transducer frequency380 kHz Response delay> 10 s, relay< 1 s, LEDs Indicators/operating means LED redLED 1: overfill indicationLED 4: underfill indication LED green/yellowLED 2: overfill warning and normal operation LED 3: normal operation and underfill warning DIP switchsetting of the switch points/operating modes Electrical specifications Operating voltage10 ... 253 V DC 20 ... 253 V AC , 47 ... 63 Hz No-load supply current< 30 mA with UB = 30 V DC< 110 mA at UB = 10 V DC< 25 mA at UB = 220 V AC Output Output type3 relay outputs, normally open/closed, selectable Range hysteresis20 mm Contact loading253 V AC/150V DC, 3 A (ohm. load) Life spanelectrical: 105 switching cycles with ohmic load(3 A/253 V AC or 3 A/30 V DC)minimum contact load: 100 µA/100 mV DCmechanical: 20 x 106 switching cycles Temperature influence< 4 % Fusing≤ 3 A Slow-blow fuse per output in accordance with IEC 60127-2 Sheet 5 required. Recommendation: after a short circuit, check that the device is functioning correctly. Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 Approvals and certificates EAC conformityTR CU 004/2011 TR CU 020/2011 TR CU 037/2016 CCC approvalself-declaration Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Degree of protectionIP65 ConnectionFemale connector, V7 (7-pin), 90° Wire cross section: ≤1.5 mm2 cable diameter ∅7 ... 9 mm Material Housingcover: PC housing: PBTthreaded flange: stainless steel installation connector/cable socket: PETP Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam Mass700 g NoteIn case of loss or damage, the cable socket must be replaced by an identical cable socket (type V7-W) from Pepperl+Fuchs! Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960

Le recensioni dei nostri clienti