OPC120W-F200-R2-Ex PEPPERL+FUCHS - Part number: 70114069
Non disponibile - Backorder
Da ordinare dal produttore
4.902,99 USD

Tasse di importazione escluse

Devi essere autenticato

OPC120W-F200-R2-Ex PEPPERL+FUCHS - Part number: 70114069

PEPPERL+FUCHS

Stationary read device OPC120W-F200-R2-Ex OPC120W-F200-R2-Ex Explosion protection for use in Zone 1, Zone 2, Zone 21 and Zone 22 Reads 1-D and 2-D codes at high speeds of up to 6 m/s at 30 readings/s High depth of focus Code quality index output Logo comparison Presence detection Stationary read device OPC120W-F200-R2-Ex OPC120W-F200-R2-Ex Explosion protection for use in Zone 1, Zone 2, Zone 21 and Zone 22 Reads 1-D and 2-D codes at high speeds of up to 6 m/s at 30 readings/s High depth of focus Code quality index output Logo comparison Presence detection

MPNs 70114069, PEP70114069, OPC120W-F200-R2-Ex
Codice HS 84718000
Peso 7 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

4.902,99 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  OPC120W-F200-R2-Ex Product Description Stationary read device for hazardous area General specifications Light typeIntegrated LED lightning (white) SymbologiesData Matrix, Code 39, Code 128, Int 2 of 5, EAN13, Pharmacode Read distance60 ... 160 mm Nominal distance: 120 mm Reading fieldMinimum read field: 28 mm x 45 mmRead field at nominal distance: 44 mm x 70 mmMaximum read field: 60 mm x 95 mm Modul sizeMinimum module size: 0.3 mm Evaluation frequencyup to 30 Hz Target velocitytriggered max. 6 m/s Data Matrix Symbol sizerectangular up to 144 x 144 modules rectangular up to 16 x 48 modules Data formatASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646 Orientationomnidirectional Nominal ratings Camera TypeCMOS , Global shutter Number of pixels752 x 480 pixels Gray scale256 Image recordingreal-time , Program-controlled or triggered externally Functional safety related parameters MTTFd40.5 a Mission Time (TM)8 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: Ready for operation LED indicationfor good/poor reading Electrical specifications Operating voltage24 V DC ± 15% , PELV No-load supply currentmax. 250 mA Power consumption6 W Interface Interface typeserial , RS 232 Transfer ratemax. 115.2 kBit/s Cable lengthmax. 30 m Interface 1 Interface typeEthernet ProtocolTCP/IP Transfer rate100 MBit/s Cable lengthmax. 30 m Input Input voltageto be applied externally 24 V ± 15% PELV Number/TypeTrigger Input current10 mA at 24 V DC Switching thresholdlow: < 10 V, high: > 15 V Cable lengthmax. 30 m Output Number/TypeGOOD, BAD, Matchcode Switching typePNP Switching voltageto be applied externally 24 V ± 15 % PELV Switching current100 mA each output Cable lengthmax. 30 m Compliance with standards and directives Standard conformity Noise immunityEN 61326-1 Emitted interferenceEN 61000-6-4 Degree of protectionEN 60529 Laser classIEC 60825-1:2007 Approvals and certificates IECEx approvalIECEx INE 14.0042X ATEX approvalINERIS 14 ATEX 0035X Device type: GUBW1.D.OS-OPC120W-F200-R2 Marking II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db Ambient conditions Ambient temperature0 ... 37 °C (32 ... 98.6 °F) Mechanical specifications Connection typeConnection terminals, max. conductor cross-section 2.5 mm2 Conductor cross section0.13 ... 2.5 mm2 Cable gland3 ... 8.5 mm Enclosure coverthreaded round cover Cover fixingflamepath thread Cover sealnone, O-ring for IP66/67 Flamepath greasepetroleum jelly Degree of protectionIP66 (IP66/67 with O-ring) Material Enclosurealuminum alloy Glassthermo-resistant tempered glass Finishepoxy coated RAL 7005 (grey) Mass7 kg GroundingM6 external grounding points Classifications SystemClasscode ECLASS 11.027280103 ECLASS 10.0.127280103 ECLASS 9.027280103 ECLASS 8.027280103 ECLASS 5.127280103 ETIM 8.0EC002999 ETIM 7.0EC002999 ETIM 6.0EC002999 ETIM 5.0EC002999 UNSPSC 12.143211701 Datasheet excerpt: Technical data of  OPC120W-F200-R2-Ex Product Description Stationary read device for hazardous area General specifications Light typeIntegrated LED lightning (white) SymbologiesData Matrix, Code 39, Code 128, Int 2 of 5, EAN13, Pharmacode Read distance60 ... 160 mm Nominal distance: 120 mm Reading fieldMinimum read field: 28 mm x 45 mmRead field at nominal distance: 44 mm x 70 mmMaximum read field: 60 mm x 95 mm Modul sizeMinimum module size: 0.3 mm Evaluation frequencyup to 30 Hz Target velocitytriggered max. 6 m/s Data Matrix Symbol sizerectangular up to 144 x 144 modules rectangular up to 16 x 48 modules Data formatASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646 Orientationomnidirectional Nominal ratings Camera TypeCMOS , Global shutter Number of pixels752 x 480 pixels Gray scale256 Image recordingreal-time , Program-controlled or triggered externally Functional safety related parameters MTTFd40.5 a Mission Time (TM)8 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: Ready for operation LED indicationfor good/poor reading Electrical specifications Operating voltage24 V DC ± 15% , PELV No-load supply currentmax. 250 mA Power consumption6 W Interface Interface typeserial , RS 232 Transfer ratemax. 115.2 kBit/s Cable lengthmax. 30 m Interface 1 Interface typeEthernet ProtocolTCP/IP Transfer rate100 MBit/s Cable lengthmax. 30 m Input Input voltageto be applied externally 24 V ± 15% PELV Number/TypeTrigger Input current10 mA at 24 V DC Switching thresholdlow: < 10 V, high: > 15 V Cable lengthmax. 30 m Output Number/TypeGOOD, BAD, Matchcode Switching typePNP Switching voltageto be applied externally 24 V ± 15 % PELV Switching current100 mA each output Cable lengthmax. 30 m Compliance with standards and directives Standard conformity Noise immunityEN 61326-1 Emitted interferenceEN 61000-6-4 Degree of protectionEN 60529 Laser classIEC 60825-1:2007 Approvals and certificates IECEx approvalIECEx INE 14.0042X ATEX approvalINERIS 14 ATEX 0035X Device type: GUBW1.D.OS-OPC120W-F200-R2 Marking II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db Ambient conditions Ambient temperature0 ... 37 °C (32 ... 98.6 °F) Mechanical specifications Connection typeConnection terminals, max. conductor cross-section 2.5 mm2 Conductor cross section0.13 ... 2.5 mm2 Cable gland3 ... 8.5 mm Enclosure coverthreaded round cover Cover fixingflamepath thread Cover sealnone, O-ring for IP66/67 Flamepath greasepetroleum jelly Degree of protectionIP66 (IP66/67 with O-ring) Material Enclosurealuminum alloy Glassthermo-resistant tempered glass Finishepoxy coated RAL 7005 (grey) Mass7 kg GroundingM6 external grounding points Classifications SystemClasscode ECLASS 11.027280103 ECLASS 10.0.127280103 ECLASS 9.027280103 ECLASS 8.027280103 ECLASS 5.127280103 ETIM 8.0EC002999 ETIM 7.0EC002999 ETIM 6.0EC002999 ETIM 5.0EC002999 UNSPSC 12.143211701

Le recensioni dei nostri clienti