Timer, Counter, Tachometer KC-LCDL-48-2R-230VAC KC-LCDL-48-2R-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only) Timer, Counter, Tachometer KC-LCDL-48-2R-230VAC KC-LCDL-48-2R-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only)

MPNs 214736, PEP214736, KC-LCDL-48-2R-230VAC
Codice HS 90262000
Peso 0.14 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

403,95 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  KC-LCDL-48-2R-230VAC Product Description LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign backlighted Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supply20.4 ... 27.6 V DC, max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass143 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902 Datasheet excerpt: Technical data of  KC-LCDL-48-2R-230VAC Product Description LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign backlighted Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supply20.4 ... 27.6 V DC, max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass143 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902