KFD2-SR2-2.W.SM PEPPERL+FUCHS - Part number: 132965
Non disponibile - Backorder
Da ordinare dal produttore
342,42 USD

Tasse di importazione escluse

Devi essere autenticato

KFD2-SR2-2.W.SM PEPPERL+FUCHS - Part number: 132965

PEPPERL+FUCHS

Standstill and Rotational Direction Monitor KFD2-SR2-2.W.SM KFD2-SR2-2.W.SM 2-channel signal conditioner 24 V DC supply PNP/push-pull, dry contacts or NAMUR inputs Selectable frequency trip values 2 relay contact outputs Start-up override Selectable mode of operation Without line fault detection Up to SIL 2 acc. to IEC/EN 61508 Standstill and Rotational Direction Monitor KFD2-SR2-2.W.SM KFD2-SR2-2.W.SM 2-channel signal conditioner 24 V DC supply PNP/push-pull, dry contacts or NAMUR inputs Selectable frequency trip values 2 relay contact outputs Start-up override Selectable mode of operation Without line fault detection Up to SIL 2 acc. to IEC/EN 61508

MPNs 132965, PEP132965, KFD2-SR2-2.W.SM
Codice HS 90318000
Peso 0.15 kg

L'immagine del prodotto è solo a scopo illustrativo.
Il paese di origine, il codice HS e la descrizione sono forniti dal produttore e possono essere soggetti a modifiche senza preavviso. Per questo motivo, PLC-City non può essere ritenuta responsabile di eventuali discrepanze.
Venduto da PLC-CITY® e spedito dall'Italia

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

342,42 USD

Tasse di importazione escluse

Devi essere autenticato
Venduto da PLC-CITY® e spedito dall'Italia
Siamo Partner Specialista di PEPPERL+FUCHS
Spedizione espressa gratuita verso Stati Uniti
Loader...
Vedi tutti i servizi di spedizione
Richiedi un preventivo per conoscere la data di consegna

Accettiamo molti metodi di pagamento: Bonifico bancario (SEPA, ACH), Carte di debito/credito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
Maggiori informazioni sui nostri metodi di pagamento

Questo prodotto è coperto da una garanzia di 12 Mesi, valida per difetti di fabbricazione o malfunzionamenti. La garanzia non copre danni causati da uso improprio o danni accidentali.
Maggiori informazioni sulla nostra garanzia

È possibile effettuare il reso previa autorizzazione e ottenere un credito, escluso per il backorder.

Visualizza la nostra politica di reso

Ottieni il tuo preventivo personalizzato ora

Un commerciale di vendita dedicato vi assisterà per offrire il miglior prezzo e tempi di consegna.

Devi essere autenticato

Richiedi il tuo servizio tecnico personalizzato

Affidati al nostro team di tecnici esperti per una gamma di servizi personalizzati: riparazione, programmazione, manutenzione e molto altro.

Informazioni prodotto

Descrizione

Datasheet excerpt: Technical data of  KFD2-SR2-2.W.SM General specifications Signal typeDigital Input Programmingvia DIP switch and programmable Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 14+, 15- Rated voltage20 ... 30 V DC Power consumptionmax. 1.5 W Input Connection sidefield side ConnectionInput I: terminals 1+, 2+, 3- ;Input II: terminals 4+, 5+, 6- Rated valuesacc. to EN 60947-5-6 (NAMUR) Open circuit voltage/short-circuit current8 V DC / 8 mA Switching point/switching hysteresis1.2 ... 2.1 mA / 0.2 mA Line fault detectionnot available Control inputsensor power supply 8.2 V, impedance 1.2 kΩ Pulse duration> 200 µs for standstill monitoring,> 250 µs for rotation direction detecion Output Connection sidecontrol side Connectionoutput I: terminals 7, 8, 9 ;output II: terminals 10, 11, 12 Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load Minimum switch current2 mA / 24 V DC Energized/De-energized delay20 ms / 20 ms Mechanical life107 switching cycles Trip valuefor standstill monitoring:0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2) Transfer characteristics Accuracy5 % (S3 = I), 30 % (S3 = II) Start-up override5 seconds or 20 seconds, programmable Frequency range≤ 2 kHz Rotation direction detection90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µs Galvanic isolation Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Indicators/settings Display elementsLEDs Control elementsDIP switch Configurationvia DIP switches Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass150 g Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFD2-SR2-2.W.SM General specifications Signal typeDigital Input Programmingvia DIP switch and programmable Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Supply Connectionterminals 14+, 15- Rated voltage20 ... 30 V DC Power consumptionmax. 1.5 W Input Connection sidefield side ConnectionInput I: terminals 1+, 2+, 3- ;Input II: terminals 4+, 5+, 6- Rated valuesacc. to EN 60947-5-6 (NAMUR) Open circuit voltage/short-circuit current8 V DC / 8 mA Switching point/switching hysteresis1.2 ... 2.1 mA / 0.2 mA Line fault detectionnot available Control inputsensor power supply 8.2 V, impedance 1.2 kΩ Pulse duration> 200 µs for standstill monitoring,> 250 µs for rotation direction detecion Output Connection sidecontrol side Connectionoutput I: terminals 7, 8, 9 ;output II: terminals 10, 11, 12 Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load Minimum switch current2 mA / 24 V DC Energized/De-energized delay20 ms / 20 ms Mechanical life107 switching cycles Trip valuefor standstill monitoring:0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2) Transfer characteristics Accuracy5 % (S3 = I), 30 % (S3 = II) Start-up override5 seconds or 20 seconds, programmable Frequency range≤ 2 kHz Rotation direction detection90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µs Galvanic isolation Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff Indicators/settings Display elementsLEDs Control elementsDIP switch Configurationvia DIP switches Labelingspace for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Low voltage Directive 2014/35/EUEN 61010-1:2010 Conformity Electromagnetic compatibilityNE 21:2006 Degree of protectionIEC 60529:2001 InputEN 60947-5-6:2000 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protectionIP20 Connectionscrew terminals Mass150 g Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Classifications SystemClasscode ECLASS 11.027210128 ECLASS 10.0.127210128 ECLASS 9.027210128 ECLASS 8.027210190 ECLASS 5.127210121 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007

Le recensioni dei nostri clienti