Multicom 302 Riello UPS - код заказа: YSKCMC2A
нет в наличии - Дозаказ
Заказать у производителя
204,42 USD

Импортные налоги не включены

Вы должны авторизоваться

Multicom 302 Riello UPS - код заказа: YSKCMC2A

MultiCom 302 is a Modbus/Jbus converter for UPS monitoring and integration. It enables communication, alarm signalling or connection to industrial systems according to the variant, improving diagnostics, remote control and operating continuity of the installation. Riello compatibility: Riello UPS systems prepared for MultiCOM accessories. MultiCom 302 is a Modbus/Jbus converter for UPS monitoring and integration. It enables communication, alarm signalling or connection to industrial systems according to the variant, improving diagnostics, remote control and operating continuity of the installation. Riello compatibility: Riello UPS systems prepared for MultiCOM accessories.

MPNs YSKCMC2A, RIEYSKCMC2A
EAN 8023251004711
кода ГС 85049090
страны происхождения Италия
Weight 0.42 kg
Объёмный вес 0.42 kg

Изображение продукта предназначено только для иллюстрации.
Страна происхождения, код ГС и описание предоставлены производителем и могут быть изменены без предварительного уведомления. По этой причине PLC-City не может нести ответственность за любые расхождения.
Продано PLC-CITY® и отправлено из Италии

Мы принимаем много способов оплаты: Банковский перевод (SEPA, ACH), Дебетовые/ Кредитные карты (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Banbancontact, blik, eps, giropay, Przelewy24, WhateCeCPay.
Подробнее о наших методах оплаты

Этот продукт покрыт гарантией 12 месяцы, действительный для производственных дефектов или неисправностей. Гарантия не покрывает ущерб, вызванный неправильным использованием или случайным повреждением.
Узнайте больше о нашей гарантии

Возврат осуществляется только с предварительного одобрения и компенсируется магазинным кредитом. Товары по предзаказу не подлежат возврату.

Просмотреть нашу политику возврата

204,42 USD

Импортные налоги не включены

Вы должны авторизоваться
Продано PLC-CITY® и отправлено из Италии
Мы являемся авторизованным дилером Riello UPS
Бесплатная экспресс-доставка в США
Loader...
Просмотреть все услуги доставки
Запрашивать предложение, чтобы знать дату поставки

Мы принимаем много способов оплаты: Банковский перевод (SEPA, ACH), Дебетовые/ Кредитные карты (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Banbancontact, blik, eps, giropay, Przelewy24, WhateCeCPay.
Подробнее о наших методах оплаты

Этот продукт покрыт гарантией 12 месяцы, действительный для производственных дефектов или неисправностей. Гарантия не покрывает ущерб, вызванный неправильным использованием или случайным повреждением.
Узнайте больше о нашей гарантии

Возврат осуществляется только с предварительного одобрения и компенсируется магазинным кредитом. Товары по предзаказу не подлежат возврату.

Просмотреть нашу политику возврата

Получите свою персонализированную цитату сейчас

Специальный представитель поможет вам предложить лучшие цены и сроки доставки.

Вы должны авторизоваться

информацию о продукте

Описание

<div class="row"> <div class="col-xs-12"> <h3>MultiCom 302 - Modbus/Jbus converter</h3> <p>MultiCom 302 is a UPS communication accessory designed to integrate monitoring, control and signalling in IT or industrial infrastructures. Its main function is Modbus/Jbus converter, allowing statuses, alarms or operating data to be sent to external systems such as supervisors, PLCs, fieldbus networks or management software. The accessory helps transform the UPS from an isolated electrical component into a monitorable node, improving preventive maintenance, diagnostics and response to events. Selection should be based on available port, required protocol and compatibility with the UPS model.</p> <h4>Technical features</h4> <ul> <li>Modbus/Jbus protocol on RS232 or RS485 lines.</li> <li>Second independent RS232 line for PC, PLC or PowerShield3.</li> <li>UPS monitoring through serial protocols.</li> <li>Integration with industrial and supervision systems.</li> </ul> <h4>Integration process</h4> <p>Integration includes insertion into the compatible slot, port or contact wiring, communication parameter setup and alarm testing. For critical installations it is recommended to document event mapping, addresses and signalling logic.</p> <h4>Configuration software</h4> <p>Configuration through Modbus/Jbus table and connected supervision software. PowerShield3 can be used on an independent RS232 line according to documentation. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Riello UPS systems prepared for MultiCOM accessories.</p> </div> </div> <div class="row"> <div class="col-xs-12"> <h3>MultiCom 302 - Modbus/Jbus converter</h3> <p>MultiCom 302 is a UPS communication accessory designed to integrate monitoring, control and signalling in IT or industrial infrastructures. Its main function is Modbus/Jbus converter, allowing statuses, alarms or operating data to be sent to external systems such as supervisors, PLCs, fieldbus networks or management software. The accessory helps transform the UPS from an isolated electrical component into a monitorable node, improving preventive maintenance, diagnostics and response to events. Selection should be based on available port, required protocol and compatibility with the UPS model.</p> <h4>Technical features</h4> <ul> <li>Modbus/Jbus protocol on RS232 or RS485 lines.</li> <li>Second independent RS232 line for PC, PLC or PowerShield3.</li> <li>UPS monitoring through serial protocols.</li> <li>Integration with industrial and supervision systems.</li> </ul> <h4>Integration process</h4> <p>Integration includes insertion into the compatible slot, port or contact wiring, communication parameter setup and alarm testing. For critical installations it is recommended to document event mapping, addresses and signalling logic.</p> <h4>Configuration software</h4> <p>Configuration through Modbus/Jbus table and connected supervision software. PowerShield3 can be used on an independent RS232 line according to documentation. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Riello UPS systems prepared for MultiCOM accessories.</p> </div> </div>

Отзывы о нашей компании