Read head and evaluation unit VAA-2E-IER2-S-1M-V1 VAA-2E-IER2-S-1M-V1 Small plastic housing Encapsulated electronics Especially suited to small doors and coverings Multiple-flush magnet system Cable with M12 plug Read head and evaluation unit VAA-2E-IER2-S-1M-V1 VAA-2E-IER2-S-1M-V1 Small plastic housing Encapsulated electronics Especially suited to small doors and coverings Multiple-flush magnet system Cable with M12 plug

MPNs 211352, PEP211352, VAA-2E-IER2-S-1M-V1
税则号 85371091
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD301.86

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

产品信息

描述

Datasheet excerpt: Technical data of  VAA-2E-IER2-S-1M-V1 Product Description Reed safety switch for non-contact AS-Interface safety switches General specifications Detection typemagnetic assured start-up distance7 mm assured release distancemax. 40 mm Center offset± 2.5 mm at distance s = 3 mm Node typeSafety node AS-Interface specificationV3.0 Required gateway specification≥ V2.0 ProfileS-0.B IO code0 ID codeB ID1 codeF ID2 codeE Response delay< 5 ms UL File NumberE155795 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e Mission Time (TM)20 a PFHd4.29 E-8 Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA Power supplyvia AS-Interface network Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 Machinery Directive Directive 2006/42/ECEN ISO 12100-1, -2:2003 EN 1088:1995+A2:2008 Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013+A1:2019 Functional safetyISO 13849-1:2008 (up to category 3/PL e) EN ISO 12100-1, -2:2003 EN 1088:1995+A2:2008 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Shock and impact resistance30 g/11 ms Mechanical specifications Housing length36 mm Housing width26.2 mm Housing depth13 mm Degree of protectionIP67 Connectionwith fixed cable and M12 connector, 4-pin Material HousingPPS CablePUR Installationany position Cable length1 m Life span100 x 106 switching cycles Classifications SystemClasscode ECLASS 11.027272603 ECLASS 10.0.127272603 ECLASS 9.027272603 ECLASS 8.027272603 ECLASS 5.127272603 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-2E-IER2-S-1M-V1 Product Description Reed safety switch for non-contact AS-Interface safety switches General specifications Detection typemagnetic assured start-up distance7 mm assured release distancemax. 40 mm Center offset± 2.5 mm at distance s = 3 mm Node typeSafety node AS-Interface specificationV3.0 Required gateway specification≥ V2.0 ProfileS-0.B IO code0 ID codeB ID1 codeF ID2 codeE Response delay< 5 ms UL File NumberE155795 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e Mission Time (TM)20 a PFHd4.29 E-8 Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA Power supplyvia AS-Interface network Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 Machinery Directive Directive 2006/42/ECEN ISO 12100-1, -2:2003 EN 1088:1995+A2:2008 Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013+A1:2019 Functional safetyISO 13849-1:2008 (up to category 3/PL e) EN ISO 12100-1, -2:2003 EN 1088:1995+A2:2008 Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Shock and impact resistance30 g/11 ms Mechanical specifications Housing length36 mm Housing width26.2 mm Housing depth13 mm Degree of protectionIP67 Connectionwith fixed cable and M12 connector, 4-pin Material HousingPPS CablePUR Installationany position Cable length1 m Life span100 x 106 switching cycles Classifications SystemClasscode ECLASS 11.027272603 ECLASS 10.0.127272603 ECLASS 9.027272603 ECLASS 8.027272603 ECLASS 5.127272603 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535