VAA-2E1A-G10-SAJ/EA2J-1M PEPPERL+FUCHS - Part number: 229182
PEPPERL+FUCHS
AS-Interface safety module VAA-2E1A-G10-SAJ/EA2J-1M VAA-2E1A-G10-SAJ/EA2J-1M Connection of contact safety switches, e.g. EMERGENCY STOP button Applications up to PLe Modular safety solution Ultra-compact enclosure Degree of protection IP67 AS-Interface safety module VAA-2E1A-G10-SAJ/EA2J-1M VAA-2E1A-G10-SAJ/EA2J-1M Connection of contact safety switches, e.g. EMERGENCY STOP button Applications up to PLe Modular safety solution Ultra-compact enclosure Degree of protection IP67
MPNs 229182, PEP229182, VAA-2E1A-G10-SAJ/EA2J-1M
税则号 85371091
Weight
0.2 kg
产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货
安全支付
等等
我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息
12个月 保修
本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
查看所有运输服务
Shipping:
到
的
Estimated delivery:
The selected carrier does not apply to this product
请求报价以知道交货日期
安全支付
等等
我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息
12个月 保修
本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固
产品信息
描述
Datasheet excerpt: Technical data of
VAA-2E1A-G10-SAJ/EA2J-1M
Product Description
G10 safety module2 safety inputs and1 standard electronic output
General specifications
Node typeSafety-Slave
AS-Interface specificationV3.0
Required master specification≥ V2.1
UL File NumberE223772 "For use in NFPA 79 Applications only"
Indicators/operating means
LED FLTerror display; LED redred: communication error or address is 0
LED AS-iAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0
LED INswitching state (input); 2 LED yellow
LED OUTSwitching state (output); LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV)
Rated operating current≤ 90 mA
Protection classIII
Surge protectionovervoltage category III
Rated insulation voltage32 V
Pulse withstand voltage0.8 kV
Input
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Currentinput current limited ≤ 15 mA,short-circuit protected
Output
Number/Type1 conventional electronic output, PNP
Supplyfrom AS-Interface
Voltage(UASI - 7.0 V) ≤ UOUT ≤ UASI
Current50 mA , short-circuit/overload protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 61140:2009
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityIEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005
Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Programming instructions
ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 OUT 1
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Approvals and certificates
UL approvalcULus Listed, Type 1 enclosure
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Relative humidity< 95 %
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3
Mechanical specifications
Degree of protectionIP67This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE
ConnectionAS-Interface: AS-Interface flat cable Inputs/outputs: open conductor ends
Material
Contactsopen conductor ends with connector sleeves
HousingPBT
CablePUR
Mounting screwStainless steel 1.4305 / AISI 303
Cable
Sheath diameter∅4.8 mm
Bending radius> 8 x cable diameter, fixed > 10 x cable diameter, moving not appropriate for conveyor chains
Colorblack
Cores6 x 0.25 mm2
Length1 m
Mass200 g
Tightening torque, fastening screws1.65 Nm
Classifications
SystemClasscode
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535
Datasheet excerpt: Technical data of
VAA-2E1A-G10-SAJ/EA2J-1M
Product Description
G10 safety module2 safety inputs and1 standard electronic output
General specifications
Node typeSafety-Slave
AS-Interface specificationV3.0
Required master specification≥ V2.1
UL File NumberE223772 "For use in NFPA 79 Applications only"
Indicators/operating means
LED FLTerror display; LED redred: communication error or address is 0
LED AS-iAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0
LED INswitching state (input); 2 LED yellow
LED OUTSwitching state (output); LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV)
Rated operating current≤ 90 mA
Protection classIII
Surge protectionovervoltage category III
Rated insulation voltage32 V
Pulse withstand voltage0.8 kV
Input
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Currentinput current limited ≤ 15 mA,short-circuit protected
Output
Number/Type1 conventional electronic output, PNP
Supplyfrom AS-Interface
Voltage(UASI - 7.0 V) ≤ UOUT ≤ UASI
Current50 mA , short-circuit/overload protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 61140:2009
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityIEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005
Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Programming instructions
ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 OUT 1
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Approvals and certificates
UL approvalcULus Listed, Type 1 enclosure
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Relative humidity< 95 %
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3
Mechanical specifications
Degree of protectionIP67This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE
ConnectionAS-Interface: AS-Interface flat cable Inputs/outputs: open conductor ends
Material
Contactsopen conductor ends with connector sleeves
HousingPBT
CablePUR
Mounting screwStainless steel 1.4305 / AISI 303
Cable
Sheath diameter∅4.8 mm
Bending radius> 8 x cable diameter, fixed > 10 x cable diameter, moving not appropriate for conveyor chains
Colorblack
Cores6 x 0.25 mm2
Length1 m
Mass200 g
Tightening torque, fastening screws1.65 Nm
Classifications
SystemClasscode
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535