VAA-2E2A-G12-SAJ/EA2L PEPPERL+FUCHS - Part number: 193671
缺货 - 延期交货
要从制造商订购
USD358.22

不含进口税

必须记录您

VAA-2E2A-G12-SAJ/EA2L PEPPERL+FUCHS - Part number: 193671

PEPPERL+FUCHS

AS-Interface safety module VAA-2E2A-G12-SAJ/EA2L VAA-2E2A-G12-SAJ/EA2L Switchable internal logic operation of the inputs and outputs via parameter bit One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch DIN rail mounting AS-Interface certificate AS-Interface safety module VAA-2E2A-G12-SAJ/EA2L VAA-2E2A-G12-SAJ/EA2L Switchable internal logic operation of the inputs and outputs via parameter bit One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch DIN rail mounting AS-Interface certificate

MPNs 193671, PEP193671, VAA-2E2A-G12-SAJ/EA2L
税则号 85371091
Weight 0.2 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD358.22

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  VAA-2E2A-G12-SAJ/EA2L Product Description G12 safety module, 2 safety inputs and 2 standard electronic outputs General specifications Node typeSafety node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 ProfileS-7.B IO code7 ID codeB ID1 codeF ID2 code0 UL File NumberE223772 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e CategoryCat. 4 MTTFdno significant contribution to MTTFd of the overall system PFHdno significant contribution to PFH of the overall system PFDno significant contribution to PFD of the overall system Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 2 LED yellow LED OUTSwitching status (output); 2 yellow/red LEDs Yellow: output activeRed: output overload Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 50 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Rated insulation voltage40 V Pulse withstand voltage0.5 kV Input Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input. Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant Output Number/Type2 conventional electronic outputs, PNP Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) Current1.5 A per output , short-circuit protected Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 Machinery Directive Directive 2006/42/ECEN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005 Standard conformity Insulation coordinationEN 60947-1:2007 Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 60947-1, NFPA 79, IEC 60204-1:2007 Emitted interferenceEN 61000-6-4:2007/A1:2011 AS-InterfaceEN 62026-2:2013+A1:2019 Noise immunityIEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005 Functional safetyISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3) StandardsNFPA 79:2007 ER 1 Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass200 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-2E2A-G12-SAJ/EA2L Product Description G12 safety module, 2 safety inputs and 2 standard electronic outputs General specifications Node typeSafety node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 ProfileS-7.B IO code7 ID codeB ID1 codeF ID2 code0 UL File NumberE223772 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e CategoryCat. 4 MTTFdno significant contribution to MTTFd of the overall system PFHdno significant contribution to PFH of the overall system PFDno significant contribution to PFD of the overall system Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 2 LED yellow LED OUTSwitching status (output); 2 yellow/red LEDs Yellow: output activeRed: output overload Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 50 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Rated insulation voltage40 V Pulse withstand voltage0.5 kV Input Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input. Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant Output Number/Type2 conventional electronic outputs, PNP Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) Current1.5 A per output , short-circuit protected Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 Machinery Directive Directive 2006/42/ECEN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005 Standard conformity Insulation coordinationEN 60947-1:2007 Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 60947-1, NFPA 79, IEC 60204-1:2007 Emitted interferenceEN 61000-6-4:2007/A1:2011 AS-InterfaceEN 62026-2:2013+A1:2019 Noise immunityIEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005 Functional safetyISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3) StandardsNFPA 79:2007 ER 1 Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass200 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

公司评介