订单满150欧元(最多10公斤)可享欧洲、美国和加拿大免费快递配送。
info
探索
-
Menu返回
-
品牌
-
- Technologies for:
-
Industry
-
-
Building
-
-
Electrification
-
-
- Cables
- Installation
-
Low Voltage
-
Cabinets & Enclosures
- Base/base element (enclosure/cabinet)
- Clima Control
- Door/operating panel (enclosure/cabinet)
- Electronic enclosure
- Empty cabinet
-
Energy distribution systems
- Accessories/spare parts for busbar trunks
- Accessories/spare parts for busbars
- Busbar couplers
- Busbar supports
- Busbar trunk units
- Cover caps for rail terminal bar
- Distributor assembly miniature circuit breakers (MCB)
- Distributor assembly terminal blocks
- Feed units for busbar trunk
- Main line branch terminals
- Meter cabinets equipped
- Mounting plates for distribution board
- Mounting rails
- Mounting systems for busbar trunk
- Phase barrier plates
- Tap off units for busbar trunk
- 小型配电箱
- 配电板面板
- 配电箱盖板
- Explosion proof enclosure/housing
- Front panel (enclosure/cabinet)
- Keys for enclosures/cabinets
- Lock systems for enclosure/cabinet
- Mounting accessories (enclosure/cabinet)
- Network cabinet
- Network/server enclosure
-
Circuit Breakers
- Auxiliary contact block
- Busbar adapters
- Device circuit breaker
- Earth leakage circuit breaker
- Fuse switch disconnector
- Fuses
- Main line circuit breaker
- Miniature circuit breaker (MCB)
- Off-load switches
-
Power Circuit Breakers
- Chassis part power circuit breaker
- Door coupling handles
- Handle for power circuit breaker
- Modification set for power circuit breaker
- Motor operator for power circuit-breaker
- Phase separation plate for power circuit breaker
- Shunt release (for power circuit breaker)
- Switch spool for power circuit breaker
- Trip block for power circuit-breaker
- Under voltage coil
- Wiring set for power circuit breaker
- Residual current circuit breaker (RCCB)
- Surge protection device for power supply systems
- Trip indicator
-
command devices (Buttons, selectors, indicators)
- Accessories/spare parts for command devices
- Accessories/spare parts for emergency stop pull cord switch
- Acoustic indicator
- Adapter for command devices
- Buttons
- Control circuit devices combination in enclosure
- Control switch, Joystick
- Emergency stop complete
- Emergency stop pull cord switch
- Enclosure for control circuit devices
- Foot switch
- Legend plate for control circuit devices
- Potentiometer for command devices
- Protective cap for command devices
- Selectors
- Signal towers
- Text plate for command devices
- Two-hand control device
- 指示灯 / 信号灯
- 指示灯 / 信号灯
- Contactors
- DIN 导轨适配器
- Filters for low-voltage
- Low Voltage Accessories
-
Motor start & protection
- Accessories/spare parts for electronic motor control and protection device
- Electronic overload relay
- Extension module for motor management device
- Motor management device
- Motor protection circuit-breaker
- Motor starter/motor starter combination
- Operator panel for Motor management device
- Soft starter
- Thermal overload relay
- Power supply
-
Relays
- (Fill) level monitoring relay
- Accessories/spare parts for switching relay
- Current monitoring relay
- Latching relay
- Optocoupler
- Relay socket
- Relays for thermistor protection (PTC)
- Residual current monitoring relay
- Residual current monitoring relay
- Solid state relay
- Speed-/standstill monitoring relay
- Speed-/standstill monitoring relay
- Switching relay
- Temperature monitoring relay
- Timer blocks
- Timer relay
- Voltage monitoring relay
- 安装继电器
- Surge protection module
- Switch disconnector (low voltage)
-
Terminal blocks
- (Knife) disconnect terminal block
- Accessories/spare parts for terminals
- Component plug terminal block
- Component terminal block
- Cross-connector for terminal block
- End bracket for terminal block
- Endplate and partition plate for terminal block
- Feed-through terminal block
- Fuse terminal block
- Ground terminal block
- Labelling for terminal block
- Multi level installation terminal block
- Sensor/actuator terminal block
- Shield connection clamp
- Single- and multi-pole terminal strip
- Terminal block connector
- Test plug for terminal blocks
- Transformers & coils
- 功率电容器
- 建筑工地用ASC配电箱
- 数据/信号线路浪涌保护
- 电池和电池模块
-
Cabinets & Enclosures
- Marking
- Optical and acoustic signalling
- UPS
-
-
-
Tools
-
- 联系我们
- 关于我们
- 促销
联系信息
-
PLC-City
Via Circumvallazione esterna 12
80025 Casandrino NA
意大利
Menu
-
Menu返回
-
品牌
-
- Technologies for:
-
Industry
-
-
Building
-
-
Electrification
-
-
- Cables
- Installation
-
Low Voltage
-
Cabinets & Enclosures
- Base/base element (enclosure/cabinet)
- Clima Control
- Door/operating panel (enclosure/cabinet)
- Electronic enclosure
- Empty cabinet
-
Energy distribution systems
- Accessories/spare parts for busbar trunks
- Accessories/spare parts for busbars
- Busbar couplers
- Busbar supports
- Busbar trunk units
- Cover caps for rail terminal bar
- Distributor assembly miniature circuit breakers (MCB)
- Distributor assembly terminal blocks
- Feed units for busbar trunk
- Main line branch terminals
- Meter cabinets equipped
- Mounting plates for distribution board
- Mounting rails
- Mounting systems for busbar trunk
- Phase barrier plates
- Tap off units for busbar trunk
- 小型配电箱
- 配电板面板
- 配电箱盖板
- Explosion proof enclosure/housing
- Front panel (enclosure/cabinet)
- Keys for enclosures/cabinets
- Lock systems for enclosure/cabinet
- Mounting accessories (enclosure/cabinet)
- Network cabinet
- Network/server enclosure
-
Circuit Breakers
- Auxiliary contact block
- Busbar adapters
- Device circuit breaker
- Earth leakage circuit breaker
- Fuse switch disconnector
- Fuses
- Main line circuit breaker
- Miniature circuit breaker (MCB)
- Off-load switches
-
Power Circuit Breakers
- Chassis part power circuit breaker
- Door coupling handles
- Handle for power circuit breaker
- Modification set for power circuit breaker
- Motor operator for power circuit-breaker
- Phase separation plate for power circuit breaker
- Shunt release (for power circuit breaker)
- Switch spool for power circuit breaker
- Trip block for power circuit-breaker
- Under voltage coil
- Wiring set for power circuit breaker
- Residual current circuit breaker (RCCB)
- Surge protection device for power supply systems
- Trip indicator
-
command devices (Buttons, selectors, indicators)
- Accessories/spare parts for command devices
- Accessories/spare parts for emergency stop pull cord switch
- Acoustic indicator
- Adapter for command devices
- Buttons
- Control circuit devices combination in enclosure
- Control switch, Joystick
- Emergency stop complete
- Emergency stop pull cord switch
- Enclosure for control circuit devices
- Foot switch
- Legend plate for control circuit devices
- Potentiometer for command devices
- Protective cap for command devices
- Selectors
- Signal towers
- Text plate for command devices
- Two-hand control device
- 指示灯 / 信号灯
- 指示灯 / 信号灯
- Contactors
- DIN 导轨适配器
- Filters for low-voltage
- Low Voltage Accessories
-
Motor start & protection
- Accessories/spare parts for electronic motor control and protection device
- Electronic overload relay
- Extension module for motor management device
- Motor management device
- Motor protection circuit-breaker
- Motor starter/motor starter combination
- Operator panel for Motor management device
- Soft starter
- Thermal overload relay
- Power supply
-
Relays
- (Fill) level monitoring relay
- Accessories/spare parts for switching relay
- Current monitoring relay
- Latching relay
- Optocoupler
- Relay socket
- Relays for thermistor protection (PTC)
- Residual current monitoring relay
- Residual current monitoring relay
- Solid state relay
- Speed-/standstill monitoring relay
- Speed-/standstill monitoring relay
- Switching relay
- Temperature monitoring relay
- Timer blocks
- Timer relay
- Voltage monitoring relay
- 安装继电器
- Surge protection module
- Switch disconnector (low voltage)
-
Terminal blocks
- (Knife) disconnect terminal block
- Accessories/spare parts for terminals
- Component plug terminal block
- Component terminal block
- Cross-connector for terminal block
- End bracket for terminal block
- Endplate and partition plate for terminal block
- Feed-through terminal block
- Fuse terminal block
- Ground terminal block
- Labelling for terminal block
- Multi level installation terminal block
- Sensor/actuator terminal block
- Shield connection clamp
- Single- and multi-pole terminal strip
- Terminal block connector
- Test plug for terminal blocks
- Transformers & coils
- 功率电容器
- 建筑工地用ASC配电箱
- 数据/信号线路浪涌保护
- 电池和电池模块
-
Cabinets & Enclosures
- Marking
- Optical and acoustic signalling
- UPS
-
-
-
Tools
-
- 联系我们
- 关于我们
- 促销
VAA-2E2A-G12-SAJ/EA2L PEPPERL+FUCHS - Part number: 193671
PEPPERL+FUCHS
AS-Interface safety module VAA-2E2A-G12-SAJ/EA2L VAA-2E2A-G12-SAJ/EA2L Switchable internal logic operation of the inputs and outputs via parameter bit One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch DIN rail mounting AS-Interface certificate AS-Interface safety module VAA-2E2A-G12-SAJ/EA2L VAA-2E2A-G12-SAJ/EA2L Switchable internal logic operation of the inputs and outputs via parameter bit One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Red LED per channel, lights up in the event of output overload Communication monitoring, configurable 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch DIN rail mounting AS-Interface certificate
MPNs 193671, PEP193671, VAA-2E2A-G12-SAJ/EA2L
税则号 85371091
Weight
0.2 kg
产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货
安全支付
等等
我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息
12个月 保修
本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
查看所有运输服务
Shipping:
到
的
Estimated delivery:
The selected carrier does not apply to this product
请求报价以知道交货日期
安全支付
等等
我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息
12个月 保修
本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固
产品信息
描述
Datasheet excerpt: Technical data of
VAA-2E2A-G12-SAJ/EA2L
Product Description
G12 safety module, 2 safety inputs and 2 standard electronic outputs
General specifications
Node typeSafety node
AS-Interface specificationV3.0
Required gateway specification≥ V2.1
ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
UL File NumberE223772
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
MTTFdno significant contribution to MTTFd of the overall system
PFHdno significant contribution to PFH of the overall system
PFDno significant contribution to PFD of the overall system
Indicators/operating means
LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload
LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0
LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage
LED INswitching state (input); 2 LED yellow
LED OUTSwitching status (output); 2 yellow/red LEDs Yellow: output activeRed: output overload
Electrical specifications
Auxiliary voltage (output)24 V DC ± 15 % PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 50 mA
Protection classIII
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral
Rated insulation voltage40 V
Pulse withstand voltage0.5 kV
Input
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input.
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant
Output
Number/Type2 conventional electronic outputs, PNP
Supplyfrom external auxiliary voltage UAUX
Voltage≥ (UAUX - 0.5 V)
Current1.5 A per output , short-circuit protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005
Standard conformity
Insulation coordinationEN 60947-1:2007
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 60947-1, NFPA 79, IEC 60204-1:2007
Emitted interferenceEN 61000-6-4:2007/A1:2011
AS-InterfaceEN 62026-2:2013+A1:2019
Noise immunityIEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005
Functional safetyISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3)
StandardsNFPA 79:2007 ER 1
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3
Mechanical specifications
Degree of protectionIP67
ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector
Material
HousingPBT
Mass200 g
Tightening torque, cable gland0.4 Nm
MountingMounting plate
Classifications
SystemClasscode
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535
Datasheet excerpt: Technical data of
VAA-2E2A-G12-SAJ/EA2L
Product Description
G12 safety module, 2 safety inputs and 2 standard electronic outputs
General specifications
Node typeSafety node
AS-Interface specificationV3.0
Required gateway specification≥ V2.1
ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
UL File NumberE223772
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
MTTFdno significant contribution to MTTFd of the overall system
PFHdno significant contribution to PFH of the overall system
PFDno significant contribution to PFD of the overall system
Indicators/operating means
LED FAULTerror display; LED redred: communication error or address is 0red flashing: Output supply overload
LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0
LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage
LED INswitching state (input); 2 LED yellow
LED OUTSwitching status (output); 2 yellow/red LEDs Yellow: output activeRed: output overload
Electrical specifications
Auxiliary voltage (output)24 V DC ± 15 % PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 50 mA
Protection classIII
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral
Rated insulation voltage40 V
Pulse withstand voltage0.5 kV
Input
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input.
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant
Output
Number/Type2 conventional electronic outputs, PNP
Supplyfrom external auxiliary voltage UAUX
Voltage≥ (UAUX - 0.5 V)
Current1.5 A per output , short-circuit protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005
Standard conformity
Insulation coordinationEN 60947-1:2007
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 60947-1, NFPA 79, IEC 60204-1:2007
Emitted interferenceEN 61000-6-4:2007/A1:2011
AS-InterfaceEN 62026-2:2013+A1:2019
Noise immunityIEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005
Functional safetyISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3)
StandardsNFPA 79:2007 ER 1
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3
Mechanical specifications
Degree of protectionIP67
ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector
Material
HousingPBT
Mass200 g
Tightening torque, cable gland0.4 Nm
MountingMounting plate
Classifications
SystemClasscode
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535