AS-Interface actuator module VBA-2A-G10-E2L-1M-2V1-W VBA-2A-G10-E2L-1M-2V1-W Ultra-compact enclosure Gold-plated and machined contacts One piece housing Degree of protection IP68 / IP69K Direct connection via cable outlet AS-Interface actuator module VBA-2A-G10-E2L-1M-2V1-W VBA-2A-G10-E2L-1M-2V1-W Ultra-compact enclosure Gold-plated and machined contacts One piece housing Degree of protection IP68 / IP69K Direct connection via cable outlet

MPNs 244950, PEP244950, VBA-2A-G10-E2L-1M-2V1-W
税则号 85371091
Weight 0.1 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD148.79

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
至 美国 从 USD27.36 开始 由 DHL Express Worldwide
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

产品信息

描述

Datasheet excerpt: Technical data of  VBA-2A-G10-E2L-1M-2V1-W Product Description G10 ultra compact module2 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 "For use in NFPA 79 Applications only" Functional safety related parameters MTTFd516 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or overload of outputs or external auxiliary voltage UAUX missing LED AS-iAS-Interface voltage; LED green LED OUTSwitching state (output); 2 LED yellow Electrical specifications Auxiliary voltage20 ... 30 V DC PELV Rated operating voltage18.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA / max. 60 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Output Number/Type2 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) Current2 A per output, TB ≤ 40°C: 4 A total, 40°C < TB ≤ 70°C: 3 A total , overload and short-circuit protected Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 61140:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-8.A.E IO code8 ID codeA ID1 code7 ID2 codeE Data bits (function via AS-Interface)InputOutput D0 - OUT1 D1 - OUT2 D2 - - D3 - - Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Approvals and certificates UL approvalcULus Listed, Type 1 enclosure Maximum permissible ambient temperaturemax. 65 °C (max. 149 °F) Ambient conditions Ambient temperature-40 ... 70 °C (-40 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionIP67 IP67 / IP68 / IP69K with flat cable VAZ-FK-S-* ConnectionAS-Interface/UAUX: AS-Interface flat cable Outputs & matching connector: M12 round connector, 4-pin, A-coded, according to IEC 61076-2-101:2012 Material ContactsCuSn / Au HousingPBT PC BodyPUR, black CablePUR Mounting screwStainless steel 1.4305 / AISI 303 Cable Sheath diameter∅4,3 mm Colorblack Cores3 x 0.34 mm2 Length1 m Mass100 g Tightening torque, fastening screws1.65 Nm Tightening torque, cable gland0.4 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2A-G10-E2L-1M-2V1-W Product Description G10 ultra compact module2 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 "For use in NFPA 79 Applications only" Functional safety related parameters MTTFd516 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or overload of outputs or external auxiliary voltage UAUX missing LED AS-iAS-Interface voltage; LED green LED OUTSwitching state (output); 2 LED yellow Electrical specifications Auxiliary voltage20 ... 30 V DC PELV Rated operating voltage18.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA / max. 60 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Output Number/Type2 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) Current2 A per output, TB ≤ 40°C: 4 A total, 40°C < TB ≤ 70°C: 3 A total , overload and short-circuit protected Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 61140:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-8.A.E IO code8 ID codeA ID1 code7 ID2 codeE Data bits (function via AS-Interface)InputOutput D0 - OUT1 D1 - OUT2 D2 - - D3 - - Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Approvals and certificates UL approvalcULus Listed, Type 1 enclosure Maximum permissible ambient temperaturemax. 65 °C (max. 149 °F) Ambient conditions Ambient temperature-40 ... 70 °C (-40 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionIP67 IP67 / IP68 / IP69K with flat cable VAZ-FK-S-* ConnectionAS-Interface/UAUX: AS-Interface flat cable Outputs & matching connector: M12 round connector, 4-pin, A-coded, according to IEC 61076-2-101:2012 Material ContactsCuSn / Au HousingPBT PC BodyPUR, black CablePUR Mounting screwStainless steel 1.4305 / AISI 303 Cable Sheath diameter∅4,3 mm Colorblack Cores3 x 0.34 mm2 Length1 m Mass100 g Tightening torque, fastening screws1.65 Nm Tightening torque, cable gland0.4 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

公司评介