AS-Interface printed circuit board VBA-2E1A-CB-N/E2-S VBA-2E1A-CB-N/E2-S A/B node with extended addressing possibility for up to 62 nodes Communication monitoring Inputs according to NAMUR in acc. with EN 60947-5-6 Power supply of inputs and the output from AS-Interface Function display for bus and inputs Lead breakage and short-circuit monitoring of the output Connection via screw terminals AS-Interface printed circuit board VBA-2E1A-CB-N/E2-S VBA-2E1A-CB-N/E2-S A/B node with extended addressing possibility for up to 62 nodes Communication monitoring Inputs according to NAMUR in acc. with EN 60947-5-6 Power supply of inputs and the output from AS-Interface Function display for bus and inputs Lead breakage and short-circuit monitoring of the output Connection via screw terminals

MPNs 127548, PEP127548, VBA-2E1A-CB-N/E2-S
税则号 85371091
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD301.59

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

产品信息

描述

Datasheet excerpt: Technical data of  VBA-2E1A-CB-N/E2-S Product Description Printed circuit board module2 NAMUR inputs and 1 electronic output General specifications Node typeA/B node Indicators/operating means LED PWR/FAULTdual LED green/redLED 1 green: AS-Interface voltage OKLED 1 red: communication error or address is 0LED 1 green/red flashing: short-circuit or lead breakage LED IN2 LEDs yellow;LED 2 yellow illuminated: switching state IN1 ON, otherwise OFFLED 3 yellow illuminated: switching state IN2 ON, otherwise OFF Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 150 mA Protection classIII Input Number/Type2 inputs for NAMUR Sensors Supplyfrom AS-Interface Voltage8 V Input current≤ 8 mA (limited internally) Switching pointOFF ≤ 1.2 mAON ≥ 2.1 mA according to DIN EN 60947-5-6 Output Number/Type1 electronic output, switched low, overload and short-circuit proof, lead breakage and short-circuit monitored Supplyfrom AS-Interface Voltage21 ... 31 V Currentmax. 100 mA Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Programming instructions ProfileS-D.A.E IO codeD ID codeA ID1 code7 ID2 codeE Data bits (function via AS-Interface)InputOutput D0 - OUT1 D1 - - D2 IN1 - D3 IN2 - Parameter bits (programmable via AS-i)function P0not used P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 (completely fitted) according to EN 60529 Connectionscrew terminal strip max. conductor cross section 1 mm2 Mass20 g Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E1A-CB-N/E2-S Product Description Printed circuit board module2 NAMUR inputs and 1 electronic output General specifications Node typeA/B node Indicators/operating means LED PWR/FAULTdual LED green/redLED 1 green: AS-Interface voltage OKLED 1 red: communication error or address is 0LED 1 green/red flashing: short-circuit or lead breakage LED IN2 LEDs yellow;LED 2 yellow illuminated: switching state IN1 ON, otherwise OFFLED 3 yellow illuminated: switching state IN2 ON, otherwise OFF Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 150 mA Protection classIII Input Number/Type2 inputs for NAMUR Sensors Supplyfrom AS-Interface Voltage8 V Input current≤ 8 mA (limited internally) Switching pointOFF ≤ 1.2 mAON ≥ 2.1 mA according to DIN EN 60947-5-6 Output Number/Type1 electronic output, switched low, overload and short-circuit proof, lead breakage and short-circuit monitored Supplyfrom AS-Interface Voltage21 ... 31 V Currentmax. 100 mA Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Programming instructions ProfileS-D.A.E IO codeD ID codeA ID1 code7 ID2 codeE Data bits (function via AS-Interface)InputOutput D0 - OUT1 D1 - - D2 IN1 - D3 IN2 - Parameter bits (programmable via AS-i)function P0not used P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 (completely fitted) according to EN 60529 Connectionscrew terminal strip max. conductor cross section 1 mm2 Mass20 g Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

公司评介