AS-Interface safety module VBA-4E1A-KE3-ZEJ/SR VBA-4E1A-KE3-ZEJ/SR Safety output module with diagnostic node Safe relay output with galvanically isolated contact sets Assigns a complete address for the safe output and one A/B address for the inputs 4 inputs can be used either for diagnostics and EDM or as standard inputs Applications up to category 4/PL e/SIL 3 Several safe output modules can be grouped into one enabling circuit AS-Interface safety module VBA-4E1A-KE3-ZEJ/SR VBA-4E1A-KE3-ZEJ/SR Safety output module with diagnostic node Safe relay output with galvanically isolated contact sets Assigns a complete address for the safe output and one A/B address for the inputs 4 inputs can be used either for diagnostics and EDM or as standard inputs Applications up to category 4/PL e/SIL 3 Several safe output modules can be grouped into one enabling circuit

MPNs 203796, PEP203796, VBA-4E1A-KE3-ZEJ/SR
税则号 85371091
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD749.85

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

1 可从合作伙伴处获得 发送请求以了解价格和交货时间
必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  VBA-4E1A-KE3-ZEJ/SR Product Description KE3 control cabinet module, 4 inputs, 1 control-safe relay output General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e Indicators/operating means LED FAULTerror display; LED redred: communication error LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow LED OUTFor flashing patterns see diagnostics table LED ALARMPLC reports alarm; red LED Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V DC Current loading capacity≤ 90 mA, overload- and short-circuit proof (INT) Input current≤ 8 mA (limited internally) Sensor supply≤ 90 mA Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type1 safety relay output Supplyfrom AS-Interface Nominal load Per contact3 A / 24 V DC; 3 A / 230 V AC Usage categoryDC-13 and AC-15 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.A.E IO code7 ID codeA ID1 code5 (Can be changed to 7 or F) ID2 codeE Data bits (function via AS-Interface)InputOutput D0 E0 LED ALARM Diagnosis (see table Device colors) D1 E1 OUT1 (see P1) D2 E2 - D3 E3 = 1.Y1 - Parameter bits (programmable via AS-i)function P0not used P1Output linkage:P1 = 1: safe output switches on release.P1 = 0: safe output switches on release and OUT1=1 P2ID1=5not usedID1=7 or FP2 = 0 IN3 is inputP2 = 1 IN3 notifies of release P3not used Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E1A-KE3-ZEJ/SR Product Description KE3 control cabinet module, 4 inputs, 1 control-safe relay output General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e Indicators/operating means LED FAULTerror display; LED redred: communication error LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow LED OUTFor flashing patterns see diagnostics table LED ALARMPLC reports alarm; red LED Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V DC Current loading capacity≤ 90 mA, overload- and short-circuit proof (INT) Input current≤ 8 mA (limited internally) Sensor supply≤ 90 mA Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type1 safety relay output Supplyfrom AS-Interface Nominal load Per contact3 A / 24 V DC; 3 A / 230 V AC Usage categoryDC-13 and AC-15 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.A.E IO code7 ID codeA ID1 code5 (Can be changed to 7 or F) ID2 codeE Data bits (function via AS-Interface)InputOutput D0 E0 LED ALARM Diagnosis (see table Device colors) D1 E1 OUT1 (see P1) D2 E2 - D3 E3 = 1.Y1 - Parameter bits (programmable via AS-i)function P0not used P1Output linkage:P1 = 1: safe output switches on release.P1 = 0: safe output switches on release and OUT1=1 P2ID1=5not usedID1=7 or FP2 = 0 IN3 is inputP2 = 1 IN3 notifies of release P3not used Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535