VBA-4E4A-CB10-ZEJ/E0J-FL PEPPERL+FUCHS - Part number: 324473
缺货 - 延期交货
要从制造商订购
USD157.63

不含进口税

必须记录您

VBA-4E4A-CB10-ZEJ/E0J-FL PEPPERL+FUCHS - Part number: 324473

PEPPERL+FUCHS

AS-Interface printed circuit board module VBA-4E4A-CB10-ZEJ/E0J-FL VBA-4E4A-CB10-ZEJ/E0J-FL Integrated communication monitoring function Outputs short-circuit and overload proof Supply of the inputs and the outputs from AS-Interface Function display for bus, inputs and outputs Connection via lead AS-Interface printed circuit board module VBA-4E4A-CB10-ZEJ/E0J-FL VBA-4E4A-CB10-ZEJ/E0J-FL Integrated communication monitoring function Outputs short-circuit and overload proof Supply of the inputs and the outputs from AS-Interface Function display for bus, inputs and outputs Connection via lead

MPNs 324473, PEP324473, VBA-4E4A-CB10-ZEJ/E0J-FL
税则号 85371091
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD157.63

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

产品信息

描述

Datasheet excerpt: Technical data of  VBA-4E4A-CB10-ZEJ/E0J-FL Product Description Printed circuit board module4 inputs/4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specification≥ V3.0 UL File NumberE223772 MTBF267 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV) Rated operating current≤ 40 mA (without inputs/outputs)/max. 160 mA Protection classIII Surge protectionUe: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type4 inputs for mechanical contacts or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage12 ... 31 V Current loading capacity≤ 100 mA Total including output current, overload and short-circuit proof Input current≤ 4 mA (limited internally) Switching point 0 (unattenuated)≤ 0.15 mA 1 (attenuated)≥ 1.3 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, NPN, overload proof and short-circuit proof Supplyfrom AS-Interface Voltage12 ... 31 V Current≤ 100 mA per output, ≤ 100 mA in total, including input supply Usage categoryDC-1 "general use" (ohmic and weak inductive loads in accordance with IEC 60947) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Approvals and certificates UL approvalProtection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 5000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g, 57 Hz ... 150 Hz, 10 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 according to EN 60529 Connection200 mm, PVC cable 0.5 mm2 Material HousingPolyamide hot-melt adhesive Mass33 g NoteThis device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E4A-CB10-ZEJ/E0J-FL Product Description Printed circuit board module4 inputs/4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specification≥ V3.0 UL File NumberE223772 MTBF267 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV) Rated operating current≤ 40 mA (without inputs/outputs)/max. 160 mA Protection classIII Surge protectionUe: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type4 inputs for mechanical contacts or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage12 ... 31 V Current loading capacity≤ 100 mA Total including output current, overload and short-circuit proof Input current≤ 4 mA (limited internally) Switching point 0 (unattenuated)≤ 0.15 mA 1 (attenuated)≥ 1.3 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, NPN, overload proof and short-circuit proof Supplyfrom AS-Interface Voltage12 ... 31 V Current≤ 100 mA per output, ≤ 100 mA in total, including input supply Usage categoryDC-1 "general use" (ohmic and weak inductive loads in accordance with IEC 60947) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Approvals and certificates UL approvalProtection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 5000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g, 57 Hz ... 150 Hz, 10 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 according to EN 60529 Connection200 mm, PVC cable 0.5 mm2 Material HousingPolyamide hot-melt adhesive Mass33 g NoteThis device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

公司评介