NJ2-11-SN PEPPERL+FUCHS - Part number: 70133159
缺货 - 延期交货
要从制造商订购
USD195.86

不含进口税

必须记录您

NJ2-11-SN PEPPERL+FUCHS - Part number: 70133159

PEPPERL+FUCHS

Inductive sensor NJ2-11-SN NJ2-11-SN 2 mm flush Usable up to SIL 3 acc. to IEC 61508 Degree of protection IP68 ATEX-/IECEx-approvals for zone 0/1/20/21 (Ex i) ATEX-/IECEx-approvals for zone 2/22 (Ex ec/tc) Inductive sensor NJ2-11-SN NJ2-11-SN 2 mm flush Usable up to SIL 3 acc. to IEC 61508 Degree of protection IP68 ATEX-/IECEx-approvals for zone 0/1/20/21 (Ex i) ATEX-/IECEx-approvals for zone 2/22 (Ex ec/tc)

MPNs 70133159, PEP70133159, NJ2-11-SN
税则号 85365090
Weight N/A

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD195.86

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

1 可从合作伙伴处获得 发送请求以了解价格和交货时间
必须记录您

产品信息

描述

Datasheet excerpt: Technical data of  NJ2-11-SN General specifications Switching functionNormally closed (NC) Output typeNAMUR with safety function Rated operating distance2 mm Installationflush Assured operating distance0 ... 1.62 mm Reduction factor rAl 0.4 Reduction factor rCu 0.3 Reduction factor r304 0.85 Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 3000 Hz Suitable for 2:1 technologyyes , with reverse polarity protection diode Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Functional safety related parameters Safety Integrity Level (SIL)SIL 3 MTTFd10660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0092X Equipment protection level GbIECEx PTB 11.0092X Equipment protection level Gc (ec)IECEx TUR 21.0017X Equipment protection level DaIECEx PTB 11.0092X Equipment protection level Dc (tc)IECEx TUR 21.0018X Equipment protection level MbIECEx PTB 11.0092X ATEX approval Equipment protection level GaPTB 00 ATEX 2049 X Equipment protection level GbPTB 00 ATEX 2049 X Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X Equipment protection level DaPTB 00 ATEX 2049 X Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0454 CCC approval Hazardous Location2020322315002308 NEPSI approval NEPSI certificateGYJ16.1392X TIIS approvalon request Ambient conditions Ambient temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typecable Housing materialValox (PBT) , black Sensing faceValox (PBT) , black Degree of protectionIP68 Cable Cable diameter4.8 mm ± 0.2 mm Bending radius> 10 x cable diameter Materialsilicone Core cross section0.34 mm2 Length2 m General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027272401 ECLASS 10.0.127272401 ECLASS 9.027272401 ECLASS 8.027272401 ECLASS 5.127272401 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NJ2-11-SN General specifications Switching functionNormally closed (NC) Output typeNAMUR with safety function Rated operating distance2 mm Installationflush Assured operating distance0 ... 1.62 mm Reduction factor rAl 0.4 Reduction factor rCu 0.3 Reduction factor r304 0.85 Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 3000 Hz Suitable for 2:1 technologyyes , with reverse polarity protection diode Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Functional safety related parameters Safety Integrity Level (SIL)SIL 3 MTTFd10660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0092X Equipment protection level GbIECEx PTB 11.0092X Equipment protection level Gc (ec)IECEx TUR 21.0017X Equipment protection level DaIECEx PTB 11.0092X Equipment protection level Dc (tc)IECEx TUR 21.0018X Equipment protection level MbIECEx PTB 11.0092X ATEX approval Equipment protection level GaPTB 00 ATEX 2049 X Equipment protection level GbPTB 00 ATEX 2049 X Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X Equipment protection level DaPTB 00 ATEX 2049 X Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X UL approvalcULus Listed, General Purpose Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0454 CCC approval Hazardous Location2020322315002308 NEPSI approval NEPSI certificateGYJ16.1392X TIIS approvalon request Ambient conditions Ambient temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typecable Housing materialValox (PBT) , black Sensing faceValox (PBT) , black Degree of protectionIP68 Cable Cable diameter4.8 mm ± 0.2 mm Bending radius> 10 x cable diameter Materialsilicone Core cross section0.34 mm2 Length2 m General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027272401 ECLASS 10.0.127272401 ECLASS 9.027272401 ECLASS 8.027272401 ECLASS 5.127272401 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

公司评介