Optical reading head PGV100-F200A-B6-V15B PGV100-F200A-B6-V15B Mechanically rugged: no wearing parts, long operating life, maintenance-free PROFIBUS interface Noncontact lane tracking of a colored strip Noncontact positioning along the colored strip using Data Matrix codes Reading of Data Matrix control codes Optical reading head PGV100-F200A-B6-V15B PGV100-F200A-B6-V15B Mechanically rugged: no wearing parts, long operating life, maintenance-free PROFIBUS interface Noncontact lane tracking of a colored strip Noncontact positioning along the colored strip using Data Matrix codes Reading of Data Matrix control codes

MPNs 258088, PEP258088, PGV100-F200A-B6-V15B
税则号 85437090
Weight 0.2 kg

产品图片仅供参考,具体以实物为准
原产国、HS 编码和产品描述由制造商提供,如有变更,恕不另行通知。因此,PLC-City 不对任何差异承担责任。
由 PLC-CITY® 销售并从意大利发货

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

USD3,667.69

不含进口税

必须记录您
由 PLC-CITY® 销售并从意大利发货
我们是 PEPPERL+FUCHS 的专业合作伙伴
免费快递至 美国
Loader...
查看所有运输服务
请求报价以知道交货日期

我们接受多种支付方式:银行转账(SEPA,ACH)、借记卡/信用卡(万事达、VISA、美国运通、大来、Discover、JCB、银联)、PayPal、ApplePay、GooglePay、Stripe链接支付、Cartes Bancaires、支付宝、Bancontact、blik、eps、giropay、iDeal、Przelewy24、微信支付。
有关我们付款方式的更多信息

本产品享有12个月的保修期,保修范围涵盖制造缺陷或故障。保修不包括因不当使用或意外损坏造成的损害。
进一步了解我们的保固

退货须经预先批准,仅可获得商店积分。预订商品不在退货范围内。

查看我们的退货策略

立即获取您的个性化报价

专门的销售代表将帮助您提供最佳的价格和交货时间。

必须记录您

立即申请专属技术服务

我们的专业技术团队可为您提供多种定制服务:维修、编程、维护等

产品信息

描述

Datasheet excerpt: Technical data of  PGV100-F200A-B6-V15B Product Description Read head for incident light positioning system General specifications Passage speed≤ 8 m/s Measuring rangemax. 10000 m Light typeIntegrated LED lightning (white/blue) Read distance100 mm Reading field120 mm x 80 mm Resolution± 0.2 mm   Functional safety related parameters MTTFd143 a Mission Time (TM)71 a Diagnostic Coverage (DC)0 % Indicators/operating means LED indicator7 LEDs (communication, alignment aid, status information) Electrical specifications Operating voltage15 ... 30 V DC , PELV No-load supply currentmax. 400 mA Power consumption6 W Interface Interface typePROFIBUS DP V0 ProtocolPROFIBUS DP acc. to EN 50170 Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing Interface 2 Interface typeUSB Service Input Input type1 funtion input0-level: -UBor unwired1-level: +8 V ... +UB , programmable Input impedance≥ 27 kΩ Output Output type1 to 3 switch outputs , PNP , programmable , short-circuit protected Switching voltageOperating voltage Switching current150 mA each output Standard conformity Emitted interferenceEN 61000-6-4:2007+A1:2011     Noise immunityEN 61000-6-2:2005     Shock resistanceEN 60068-2-27:2009 Vibration resistanceEN 60068-2-6:2008 Approvals and certificates UL approvalcULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Operating temperature0 ... 60 °C (32 ... 140 °F) ,   -20 ... 60 °C (-4 ... 140 °F) (noncondensing; prevent icing on the lens!) Relative humidity90 % , noncondensing Mechanical specifications Connection type8-pin, M12x1 connector, standard (supply+IO) 5-pin, M12x1 socket, B-coded (Bus Out) 5-pin, M12x1 connector, B-coded (Bus In) Housing width70 mm Housing height70 mm Degree of protectionIP67 Material HousingPC/ABS Mass200 g Classifications SystemClasscode ECLASS 11.027310101 ECLASS 10.0.127310101 ECLASS 9.027310101 ECLASS 8.027310101 ECLASS 5.127310101 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 UNSPSC 12.143211711 Datasheet excerpt: Technical data of  PGV100-F200A-B6-V15B Product Description Read head for incident light positioning system General specifications Passage speed≤ 8 m/s Measuring rangemax. 10000 m Light typeIntegrated LED lightning (white/blue) Read distance100 mm Reading field120 mm x 80 mm Resolution± 0.2 mm   Functional safety related parameters MTTFd143 a Mission Time (TM)71 a Diagnostic Coverage (DC)0 % Indicators/operating means LED indicator7 LEDs (communication, alignment aid, status information) Electrical specifications Operating voltage15 ... 30 V DC , PELV No-load supply currentmax. 400 mA Power consumption6 W Interface Interface typePROFIBUS DP V0 ProtocolPROFIBUS DP acc. to EN 50170 Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing Interface 2 Interface typeUSB Service Input Input type1 funtion input0-level: -UBor unwired1-level: +8 V ... +UB , programmable Input impedance≥ 27 kΩ Output Output type1 to 3 switch outputs , PNP , programmable , short-circuit protected Switching voltageOperating voltage Switching current150 mA each output Standard conformity Emitted interferenceEN 61000-6-4:2007+A1:2011     Noise immunityEN 61000-6-2:2005     Shock resistanceEN 60068-2-27:2009 Vibration resistanceEN 60068-2-6:2008 Approvals and certificates UL approvalcULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Operating temperature0 ... 60 °C (32 ... 140 °F) ,   -20 ... 60 °C (-4 ... 140 °F) (noncondensing; prevent icing on the lens!) Relative humidity90 % , noncondensing Mechanical specifications Connection type8-pin, M12x1 connector, standard (supply+IO) 5-pin, M12x1 socket, B-coded (Bus Out) 5-pin, M12x1 connector, B-coded (Bus In) Housing width70 mm Housing height70 mm Degree of protectionIP67 Material HousingPC/ABS Mass200 g Classifications SystemClasscode ECLASS 11.027310101 ECLASS 10.0.127310101 ECLASS 9.027310101 ECLASS 8.027310101 ECLASS 5.127310101 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 UNSPSC 12.143211711

公司评介